LED BACKLIGHT

FLUKE 110 True RMS Multimeter

9V | 600V | CAT III | 400 HOURS

R3,890.00

FloatOr as low as R972.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK5166916

The Fluke 110 True-RMS Multimeter is trusted by residential and commercial electricians for troubleshooting as well as maintenance. The 110 is for professional use, where True-RMS accuracy is needed. Review the product 110 data sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Compact True-RMS meter for accurate electrical installation and troubleshooting.

The Fluke 110 True-RMS Multimeter is trusted by residential and commercial electricians for troubleshooting as well as maintenance. The 110 is ideal for professional use, where you require True-RMS accuracy. Review the product 110 data sheet for all technical specifications.

 

 

Fluke 110 True-RMS Multimeter Showcase

 

FEATURES

  • True-RMS ac voltage for accurate measurements of non-linear signals.
  • Large white LED backlight to work in poorly lit areas.
  • Resistance and continuity measurements.
  • Min/Max/Average to record signal fluctuations.
  • CAT III 600 V safety rate.

 

SET INCLUDES

  • Fluke 110 Digital Multimeter.
  • Test Lead Set.

FLUKE 110 True-RMS Multimeter

 

 

Additional information

General specifications

Maximum voltage (between any terminal and earth ground)

600V

Safety

IEC 61010-1, Pollution degree 2
IEC 61010-2-033, CAT III 600 V

Display

Digital: 6,000 counts, updates 4/sec

Bar graph

33 segments, updates 32/sec

Temperature

Operating: -10 °C to + 50 °C

Storage:-40 °C to + 60 °C

Battery

9 volt Alkaline, IEC 6LR61

Battery life

400 hours typical, without backlight

Accuracy

DC millivolts - Range

600.0 mV

DC millivolts - Resolution

0.1 mV

DC millivolts - Accuracy ±

0.5 % + 2
([% of reading] + [counts])

DC volts - Range

6.000 V, 60.00 V, 600.0 V

DC volts - Resolution

0.001 V, 0.01 V, 0.1 V

DC Volts - Accuracy ±

0.5 % + 2
([% of reading] + [counts])

AC millivolts* true-rms - Range

600.0 mV

AC millivolts* true-rms - Resolution

0.1 mV

AC millivolts* true-rms - Accuracy ±

1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
([% of reading] + [counts])

AC volts* true-rms - Range

6.000 V, 60.00 V, 600.0 V

AC volts* true-rms - Resolution

0.001 V, 0.01 V, 0.1 V

AC volts* true-rms - Accuracy ±

1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
([% of reading] + [counts])

Continuity - Range

600 Ω

Continuity - Resolution

1 Ω

Continuity - Accuracy ±

Beeper on < 20 Ω, off> 250 Ω; detects opens or shorts of 500 μs or longer.

Ohms Ω

Range: 600.0 Ω, Resolution: 0.1 Ω, Accuracy: 0.9 % + 2

Ohms kΩ

Range: 6.000 kΩ, 60.00 kΩ, 600.0 kΩ ,6.000 MΩ
Resolution: 0.001 kΩ, 0.01 kΩ, 0.1 kΩ, 0.001 MΩ
Accuracy: 0.9 % + 1

Ohms MΩ

Range: 40.00 MΩ
Resolution: 0.01 MΩ
Accuracy: 5 % + 2

Range Notes

* – All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled.

Scope of Delivery

  • Fluke 110 True-RMS Digital Multimeter.
  • Test Lead Set.

Product Warranty

The Fluke 110 carries a 3-year limited warranty against manufacture default. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Button Guide

Symbol Guide

Jack Guide

Display Guide

Safety Information

Safety Information

  • A Warning identifies conditions and procedures that are dangerous to the user.
  • To prevent possible electrical shock, fire, or personal injury: Carefully read all instructions.
  • Read all safety information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Use only correct measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Remove all probes, test leads, and accessories before the battery door is opened.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Remove the input signals before you clean the Product.
  • Have an approved technician repair the Product.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Use only specified replacement parts.
  • Use only specified replacement fuses.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not use in CAT III or CAT IV environments without the protective cap installed. The protective cap decreases the exposed probe metal to <4 mm. This decreases the possibility of arc flash from short circuits.
  • To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product to the circuit when you measure the current. Connect the Product in series with the circuit.
  • For safe operation and maintenance of the product, repair the Product before use if the batteries leak.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.