ADVANCED MEASUREMENTS

FLUKE 1663-SCH Installation Tester

500V | CAT III 500V | CAT IV 300V | 50-1000V

R62,730.00

FloatOr as low as R15,682.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK4546980

The Fluke 1663 Installation Tester delivers the full-featured functionality and advanced measurement capabilities that professional installers need. It is compact and lightweight (less than 1.3 kg) and comes with a padded carrying and waist strap for convenient handling. Review the Fluke 1663 data sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Full-featured tester for installation professionals.

The Fluke 1663 Installation Tester delivers full-featured functionality in addition to advanced measurement capabilities that professional installers need. It is compact and lightweight (less than 1.3 kg) and comes with a padded carrying and waist strap for convenient handling. The operation is intuitive and easily mastered by all levels of workers so you can put it to work immediately for quick and efficient testing to all local regulations. Review the Fluke 1663 data sheet for all technical specifications.

 

 

FEATURES

  • Tests to all local regulations and provides test results for complete documentation
  • Continuity tests at L-N, N-PE inputs
  • Tests smooth dc sensitive RCDs (Type B)
  • Earth resistance, voltage, and frequency tests
  • Offers multiple test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V
  • Wiring polarity checks to detect broken N wires.
  • Insulation resistance as well as loop and line resistance measurement.
  • Easy evaluation of the highest loop test value as a result of the Z-max memory for loop tests.
  • Fast, reliable and accurate test lead and mains cord compensation due to the unique zero adapter.
  • Motor windings measurements with continuity testing.
  • Calculates prospective earth fault current (PEFC/IK) in addition to prospective short-circuit current (PSC/IK)
  • RCD switching time and tripping level (ramp test) measurements.
  • Measures trip time and current for RCD type A & AC in one test
  • Provides automatic RCD test sequence as well as RCD variable current measurements.
  • Includes a phase sequence indicator
  • Safety rated CAT III 500V, CAT IV 300V

 

SET INCLUDES

  • Fluke 1663 Multifunction Installation Tester.
  • 6x AA (IEC LR6) cell batteries.
  • C1600 hard carrying case.
  • Zero adapter.
  • Heavy duty mains cord.
  • STD standard test lead set.
  • Padded carrying and waist strap.
  • Quick reference guide.
  • TP165X remote control probe and lead.

Additional information

AC voltage measurement

AC Volts

Range – 500 V
Resolution – 0.1 V
Accuracy 45 Hz – 66 Hz – 0.8% + 3

Input impedance

360 kΩ

Overload protection

660 V rms

Continuity testing (RLO)

Range (autoranging) – 20 Ω / 200 Ω / 2000 Ω
Resolution – 0.01 Ω / 0.1 Ω / 1 Ω
Open Circuit Voltage – >4 V

Insulation resistance measurement (RISO)

Test voltages

50-100-250-500-1000 V

Accuracy of Test voltage (at rated test current)

+10%, -0%

Test voltage

50 V
100 V
250 V
500 V
1000 V

Insulation resistance range

20 MΩ /50 MΩ
20 MΩ / 100 MΩ
20 MΩ / 200 MΩ
20 MΩ / 200 MΩ / 500 MΩ
20 MΩ / 200 MΩ / 1000 MΩ

Resolution

0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ

Test current

1 mA @ 50 kΩ
1 mA @ 100 kΩ
1 mA @ 250 kΩ
1 mA @ 500 kΩ
1 mA @ 1 MΩ

Loop and line impedance (ZI)

Range – 10 Ω / 0.001 Ω / High current mΩ mode
Resolution – 0.01 Ω / 0.1 Ω / 1 Ω

Prospective earth fault current, PSC test

Range – 1000 A / 10 kA (50 kA)
Resolution – 1 A / 0.1 kA
Computation – Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.

RCD Type

AC¹, G²,S³

Model 1663

A4, AC¹, G²,S³

RCD Notes

¹Responds to AC
²General, no delay
³Time delay
⁴Responds to pulsed signal
⁵Responds to smooth DC signal

Tripping speed test (ΔT)

Current settings¹

10-30-100-300-500-1000 mA – VAR
10-30-100 mA

Multiplier

x ½, x 1
x 5

Measurement range

RCD Type G – 310 ms, 50 ms
RCD Type S – 510 ms, 160 ms

ΔT Notes

¹1000 mA type AC only
700 mA maximum type A in VAR mode
VAR mode not available for type B.

RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)

Current range

30% to 110% of RCD rated current¹

Step size

10% of IΔN²

Dwell time

Type G – 300 ms/step
Type S – 500 ms/step

Measurement accuracy

±5%

Specified trip current ranges (EN 61008-1)

50% to 100% for Type AC
35% to 140% for Type A (>10 mA)
35% to 200% for Type A (≤10 mA)
50% to 200% for Type B
²5% for Type B

IΔN

¹30% to 150% for Type A IΔN > 10 mA
30% to 210% for Type A IΔN = 10 mA
20% to 210% for Type B

Earth Resistance Test (RE)

‎Range – 200 Ω / 2000 Ω
Resolution – 0.1 Ω / 1Ω
Frequency – 128 Hz

Output Voltage

25 V

General Specifications

Size (L x W x H)

10 x 25 x 12.5 cm

Weight (incl. batteries)

1.3 Kg

Battery size, quantity

Type AA, 6 ea.

Sealing

IP-40

Safety

Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition

Overvoltage

CAT III / 500V; CAT IV 300V

Performance

EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition

Scope of Delivery

  • Fluke 1663 Multifunction Installation Tester.
  • 6x AA (IEC LR6) cell batteries.
  • C1600 hard carrying case.
  • Zero adapter.
  • Heavy duty mains cord.
  • STD standard test lead set.
  • Padded carrying and waist strap.
  • Quick reference guide.
  • TP165X remote control probe and lead.

Product Warranty

The Fluke 1663 carries a 3-year limited warranty against manufacture default. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Safety Information

Safety Information

  • A Warning identifies conditions and procedures that are dangerous to the user.
  • To prevent possible electrical shock, fire, or personal injury: Carefully read all instructions.
  • Read all safety information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Use only correct measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Remove all probes, test leads, and accessories before the battery door is opened.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Remove the input signals before you clean the Product.
  • Have an approved technician repair the Product.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Use only specified replacement parts.
  • Use only specified replacement fuses.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not use in CAT III or CAT IV environments without the protective cap installed. The protective cap decreases the exposed probe metal to <4 mm. This decreases the possibility of arc flash from short circuits.
  • To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product to the circuit when you measure the current. Connect the Product in series with the circuit.
  • For safe operation and maintenance of the product, repair the Product before use if the batteries leak.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.