FIELD SENSE™

FLUKE T6-1000 Electrical Tester With Field Sense

17.8MM | 200 AAC | 1000 VAC | 1-100 kΩ

R9,630.00

FloatOr as low as R2,407.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK4910257

The Fluke T6-1000 Electrical Tester with FieldSense™ technology lets you quickly, and safely take True RMS voltage and current measurements without test leads. Unlike other fork testers that merely detect voltage, the T6-1000 makes actual measurements, without contacting a live, metallic conductor. Review the Fluke T6-1000 data sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Measure voltage without test leads.

The Fluke T6-1000 Electrical Tester with FieldSense™ technology lets you quickly, and safely take True RMS voltage and current measurements without test leads. Unlike other fork testers that merely detect voltage, the T6-1000 makes actual measurements, without contacting a live, metallic conductor. Just slide the 17.8 mm open fork, the widest in the industry, over a conductor and read simultaneous voltage and current values. Or simultaneous frequency and current values.

The open fork works with wires up to AWG 4/0 (120 mm2). Or, you can use the attached test leads to measure voltage DC to 1000 V. Review the Fluke T6-1000 data sheet for all technical specifications.

 

 

FEATURES

  • Measure voltage to 1000 V AC without test leads.
  • Simultaneously measure voltage and current.
  • 17.8 mm open fork is the widest in the industry.
  • Measure up to 200 A on 4/0 wires (120 mm2).
  • True RMS voltage and current to 200 A AC, 1000 V AC.
  • Measures resistance from 1 Ω to 100 kΩ.
  • FieldSense™ detects an electrical field that interacts with a T6 reference signal, showing a voltage value on the tester’s display.
  • HOLD button to temporarily freeze the reading on the screen so you can keep working with the same measurement up.
  • Easy to work in darker work environments or inside cabinets due to the large display with easy-to-read numbers.

 

SET INCLUDES

  • Fluke T6-1000 Electrical Tester.
  • Attached test leads with removable 4 mm probe caps.
  • Quick Reference Guide.

 

Additional information

Measurement Specifications

‎‎‎

FieldSense AC voltage true-RMS

Requires test leads – No
Range – 1000V
Resolution – 1V
Accuracy¹ – ± (3 % + 3 counts) 45 Hz – 66 Hz⁽²⁾⁽³⁾

FieldSense AC current true-RMS

Requires test leads – No
Range – 200.0A
Resolution – 0.1A
Accuracy¹ – ± (3% + 3 counts) 45 Hz – 66 Hz

FieldSense frequency (Hz)

Requires test leads – No
Range – 45 Hz – 66 Hz
Resolution – 1 Hz
Accuracy¹ – ± (1% + 2 counts)³

Volts AC true-RMS

Requires test leads – Yes
Range – 1000V
Resolution – 1V
Accuracy¹ – ± (1.5% + 2 counts) 45 Hz – 66 Hz

Volts DC

Requires test leads – Yes
Range – 1000V
Resolution – 1V
Accuracy¹ – ± (1% + 2 counts)

Resistance - Range 2000 Ω

Requires test leads – Yes
Resolution – 1 Ω
Accuracy¹ – ± (1% + 2 counts)

Resistance - Range 20.00 kΩ

Requires test leads – Yes
Resolution – 0.01 kΩ
Accuracy¹ – ± (1% + 2 counts)

Resistance - Range 100.0 kΩ

Requires test leads – Yes
Resolution – 0.1 kΩ
Accuracy¹ – ± (1% + 2 counts)

Notes

Accuracy¹ – ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
Accuracy² – Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
Accuracy³ – FieldSense is specified from 16 V to 100 % of range.

General Specifications

‎‎‎

Calibration

1-year calibration cycle

Dimensions

61.1 x 259.3 x 43.8 mm

Jaw opening

17.8 mm

Weight

0.35 kg (0.78 lb)

Temperature

Operating: -10 °C to +50 °C (14 °F to 122 °F)
Storage: -30 °C to +60 °C (-22 °F to +140 °F)

Altitude

Operating – 2,000 m (6,562 feet)
Storage – 10,000 m (32,808 feet)

Relative Humidity

0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
0% to 45%, 40°C to 50 °C (104 °F to 122 °F)

Battery Type and Life

2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense

Temperature coefficient

0.1 x (specified accuracy) / °C for <18°C or >28 °C
0.1 x (specified accuracy) / °C for <18°C or >28 °C

Safety

IEC/EN 61010-1: Pollution Degree 2

Electromagnetic Environment

IEC/EN 61326-1: Portable

Scope of Delivery

  • Fluke T6-1000 Electrical Tester.
  • Attached test leads with removable 4 mm probe caps.
  • Quick Reference Guide.

Product Warranty

The Fluke T6-1000 carries a 2-year limited warranty against manufacture defects. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Safety Information

Safety Information

A Warning identifies conditions and procedures that are dangerous to the user. To prevent possible electrical shock, fire, or personal injury:

  • Read all safety information before you use the Product.
  • Carefully read all instructions.
  • Do not alter the Product and use only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
    Comply with local and national safety codes. Use personal protective equipment (approved rubber gloves, face protection, and flame-resistant clothes) to prevent shock and arc blast injury where hazardous live conductors are exposed.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • T6-600/T6-1000: Examine the battery door decal for damage to this insulator. Look for any cracks, holes, or evidence of delamination. This insulator houses a laminated foil that provides a capacitive current path for the FieldSense function. This insulator provides a means of protection against electric shock when the COM probe test lead (black) is installed into the back case
  • The battery door must be closed and locked before you operate the Product.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation or exposed metal. Check test lead continuity.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Use the correct terminals, function, and range for measurements.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Keep fingers behind the finger guards on the probes.
  • Hold the Product behind the tactile barrier. See the Quick Reference Guide for this Product.
  • T6-600/T6-1000: To use the FieldSense Ground Contact, make sure the – test probe (BLACK) is stowed in the storage location in the back case before a FieldSense measurement. See the Quick Reference Guide for this Product.
  • Disconnect power and discharge all high-voltage capacitors before you measure resistance or continuity.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Do not operate the Product with covers removed or the case open. Hazardous voltage exposure is possible.
  • Have an approved technician repair the Product.
  • Use only specified replacement parts.

For safe operation and maintenance of the Product:

  • Remove batteries to prevent battery leakage and damage to the Product if it is not used for an extended period.
  • Repair the Product before use if the battery leaks.
  • Be sure that the battery polarity is correct to prevent battery leakage.
  • Clean the case with a damp cloth and detergent. Do not use abrasives or solvents.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.