BASIC INSULATION TESTING

FLUKE 1503 Insulation Tester 1Kv

4xAA | 600V AC-RMS DC | 0.01Ω-2000MΩ | IP40

R16,590.00

FloatOr as low as R4,147.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK2427883

The FLUKE 1503 Insulation Tester is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand. The 1503 is the same form factor as the Fluke 1507 but with fewer features. Review the Data Sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Handles all the basic insulation testing needs.

The Fluke 1503 Insulation Tester is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand. The 1503 is the same form factor as the Fluke 1507 but with fewer features. Review the Fluke 1503 data sheet for all technical specifications.

 

Fluke 1503 Insulation Tester Showcase

 

 FEATURES

  • Measures AC/DC voltage from 0.1 V to 600 V.
  • Offers two insulation test voltages: 500 V and 1000 V.
  • Performs insulation tests from 0.0M1Ω to 2000 MΩ
  • Added user protection as a result of the auto-discharge of capacitive voltage.
  • Provides lo-ohms earth-bond continuity (200 mA).
  • Simplifies repetitive or hard-to-reach testing with the remote test probe.
  • Saves battery power with auto power off.
  • Easier viewing due to the backlit display.
  • Features CAT IV 600 V overvoltage category rating.
  • Includes live circuit detection to prevent insulation test if voltage >30 V is detected
  • Runs on four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests.

 

SET INCLUDES

  • Fluke 1503.
  • Remote probe.
  • Test leads.
  • Test probes.
  • Alligator clips.
  • User documentation.

FLUKE 1503 Insulation Tester

Additional information

AC/DC Voltage Measurement

Input impedance

3 MΩ (nominal), < 100 pF

Common mode rejection ratio (1 kΩ unbalanced)

> 60 dB at DC, 50 or 60 Hz

AC/DC Overload Protection

600 V rms or DC

Earth Bond Resistance Measurement

Range/Resolution

20.00 Ω – 0.01 Ω
200.0 Ω – 0.1 Ω
2000 Ω – 1.0 Ω
20.00 kΩ – 0.01 kΩ

Accuracy

±(1.5% + 3)

Overload protection

2 V rms or DC

Open circuit test voltage

> 4.0 V, < 8 V

Earth Bond Resistance - Short circuit current

> 200.0 mA

Insulation Specifications

Measurement range

0.01 MΩ to 2000 MΩ

Test voltage

500 V, 1000 V

Test voltage accuracy

+ 20%, – 0%

Short circuit current

1 mA nominal

Auto discharge

Discharge time < 0.5 second for C = 1 µF or less

Live circuit indicator

Inhibit test if terminal voltage > 30 V prior to initialization of test

Maximum capacitive load

Operable with up to 1 µF load

Measure accuracy

500 V – ±(1.5% + 5)
1000 V – ±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ

General Specifications

Maximum voltage applied to any terminal

600 V AC rms or DC

Storage temperature

-40°C to 60°C (-40°F to 140°F)

Operating temperature

-20°C to 55°C (-4°F to 131°F)

Temperature coefficient

0.05 x (specified accuracy) per °C for temperatures < 18°C or > 28°C (< 64°F or > 82°F)

Relative humidity

0% to 95% @ 10°C to 30°C (50°F to 86°F)
0% to 75% @ 30°C to 40°C (86°F to 104°F)
0% to 40% @ 40°C to 55°C (104°F to 131°F)

Vibration

Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument

Shock

1-meter drop per IEC 61010-1 2nd Edition (1-meter drop test, six sides, oak floor)

Electromagnetic compatibility

In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)

Safety

Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)

Certifications

CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition

Batteries

Four AA batteries (NEDA 15A or IEC LR6)

Battery llife

Insulation test use – Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Resistance measurements – Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.

Size (H x W x L)

5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)

Weight

550 g (1.2 lb)

IP rating

IP40

Altitude

Operating – 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage) – 12,000 m

Over-range capability

110% of range

Included accessories

TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe

Scope of Delivery

  • Fluke 1503 Insulation Resistance Meter.
  • TL224 Test Leads.
  • TP74 Test Probes.
  • Clips PN 1958654 (red).
  • PN 1958646 (black).
  • Holster.
  • Remote probe.
  • User documentation.

Product Warranty

The Fluke 1503 carries a 1-year limited warranty against manufacture default. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Safety Information

Safety Information

  • A Warning identifies conditions and procedures that are dangerous to the user.
  • To prevent possible electrical shock, fire, or personal injury: Carefully read all instructions.
  • Read all safety information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Use only correct measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Remove all probes, test leads, and accessories before the battery door is opened.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Remove the input signals before you clean the Product.
  • Have an approved technician repair the Product.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Use only specified replacement parts.
  • Use only specified replacement fuses.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not use in CAT III or CAT IV environments without the protective cap installed. The protective cap decreases the exposed probe metal to <4 mm. This decreases the possibility of arc flash from short circuits.
  • To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product to the circuit when you measure the current. Connect the Product in series with the circuit.
  • For safe operation and maintenance of the product, repair the Product before use if the batteries leak.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.