Accuracy Specifications |
|
AC volts (40 Hz to 500Hz)¹ |
Range – 4.000 V, 40.00 V, 400.0 V, 1000 V
Resolution – 0.001 V, 0.01 V, 0.1 V, 1 V
Accuracy – 1.0% + 3
|
DC volts |
Range – 4.000 V, 40.00 V, 400.0 V, 1000 V
Resolution – 0.001 V, 0.01 V, 0.1 V, 1 V
Accuracy – 0.5% + 3
|
AC millivolts |
Range – 400.0 mV
Resolution – 0.1 mV
Accuracy – 3.0% + 3
|
DC millivolts |
Range – 400.0 mV
Resolution – 0.1 mV
Accuracy – 1.0% + 10
|
Diode test² |
Range – 2.000 V
Resolution – 0.001 V
Accuracy – 10%
|
Resistance (Ohms) |
Range – 400.0 Ω, 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ
Resolution – 0.1 Ω, 0.001 kΩ, 0.01 kΩ, 0.1 kΩ, 0.001 MΩ, 0.01 MΩ
Accuracy – 0.5% + 3, 0.5% + 2, 0.5% + 2, 0.5% + 2, 0.5% + 2, 1.5% + 3
|
Capacitance³ |
Range – 40.00 nF, 400.0 nF, 4.000 μF, 40.00 μF, 400.0 μF, 1000 μF
Resolution – 0.01 nF, 0.1 nF, 0.001 μF, 0.01 μF, 0.1 μF, 1 μF
Accuracy – 2% + 5, 2% + 5, 5% + 5, 5% + 5, 5% + 5, 5% + 5
|
Frequency¹ Hz (10 Hz – 100 kHz) |
Range – 50.00 Hz, 500.0 Hz, 5.000 kHz, 50.00 kHz, 100.0 kHz
Resolution – 0.01 Hz, 0.1 Hz, 0.001 kHz, 0.01 kHz, 0.1 kHz
Accuracy – 0.1% + 3
|
Duty Cycle¹ |
Range – 1% to 99%
Resolution – 0.1%
Accuracy – 1% typical⁴
|
AC current μA (40 Hz to 400 Hz) |
Range – 400.0 μA, 4000 μA
Resolution – 0.1 μA, 1 μA
Accuracy – 1.5% + 3
|
AC current mA (40 Hz to 400 Hz) |
Range – 40.00 mA, 400.0 mA
Resolution – 0.01 mA, 0.1 mA
Accuracy – 1.5% + 3
|
AC current A (40 Hz to 400 Hz) |
Range – 4.000 A, 10.00 A
Resolution – 0.001 A, 0.01 A
Accuracy – 1.5% + 3
|
DC current μA |
Range – 400.0 μA, 4000 μA
Resolution – 0.1 μA, 1 μA
Accuracy – 1.5% + 3
|
DC current mA |
Range – 40.00 mA, 400.0 mA
Resolution – 0.01 mA, 0.1 mA
Accuracy – 1.5% + 3
|
DC current A |
Range – 4.000 A, 10.00 A
Resolution – 0.001 A, 0.01 A
Accuracy – 1.5% + 3
|
Temperature - Accuracy |
Range – 50 °C- 400 °C, 0 °C- 50 °C, -55 °C- 0 °C
Resolution – 0.1C
Accuracy – 2% ±1 °C, ±2 °C, 9% ±2 °C
|
Backlight |
Yes
|
Accuracy Specifications Notes |
1. All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
4. Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90%.
|
Overload protection |
AC Volts – 1000 V¹
AC Millivolts – 400 mV
DC Volts – 1000 V¹
DC Millivolts – 400 mV
|
Input impedance (Nominal) |
AC Volts – >10 MΩ <100 pF
AC Millivolts – >1MΩ, <100 pF
DC Volts – >10 MΩ <100 pF
DC Millivolts – >1MΩ, <100 pF
|
Common mode rejection ratio |
AC Volts – 60 dB at dc, 50 Hz or 60 Hz
AC Millivolts – >80 dB at 50 Hz or 60 Hz
DC Volts – >100 dB at dc, 50 Hz or 60 Hz
DC Millivolts – >80 dB at 50 Hz or 60 Hz
|
Normal mode rejection ratio |
AC Volts – N/A
AC Millivolts – N/A
DC Volts – >60 dB at 50 Hz or 60 Hz
DC Millivolts – N/A
|
Overload Protection Notes |
1. 106 V Hz Max
|
General specifications |
|
Maximum voltage between any terminal and earth ground |
1000 V
|
Display (LCD) |
4000 counts, updates 3/sec
|
Battery type |
2 AA, NEDA 15A, IEC LR6
|
Battery life |
500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
|
General Temperature |
Operating: 0 °C to 40 °C
Storage: -30 °C to 60 °C
|
Operating humidity |
Non-condensing (<10°C) – ≤90% RH at 10 °C to 30 °C, ≤75% RH at 30 °C to 40 °C
40 MΩ range – ≤80% RH at 10 °C to 30 °C, ≤70% RH at 30 °C to 40 °C
|
General Altitude |
Operating – 2000 m
Storage – 12,000 m
|
Temperature coefficient |
0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
|
Fuse protection for current inputs |
440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
|
Size (H x W x L) |
183 x 91 x 49.5 mm
|
Weight |
455 g
|
IP rating |
IP 40
|
Safety |
IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
|
Electromagnetic environment |
IEC 61326-1: Portable
|
Electromagnetic compatibility |
Applies to use in Korea only
|
Electromagnetic compatibility notes |
Class A equipment (industrial broadcasting and communication equipment)¹
1. This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.
|
Reviews
There are no reviews yet.