DUTY CYCLE MEASUREMENT

FLUKE 17B+ Compact Digital Multimeter

AA | 1000V | 600V CAT III | 500 HOURS

R4,460.00

FloatOr as low as R1,115.00 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK4404246

The Fluke 17B+ Digital Multimeter is ideal when your job requires that you have a rugged, reliable and accurate digital multimeter. Easy to use with one hand, even with gloves on, the Fluke 17B+ offers everything you need. Review the Fluke 17B+ data sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Fluke quality is always within your reach.

The Fluke 17B+ Digital Multimeter is ideal when your job requires that you have a rugged, reliable and accurate digital multimeter. Easy to use with one hand, even with gloves on, the Fluke 17B+ offers everything you need. Review the Fluke 17B+ data sheet for all technical specifications.

 

Fluke 17B+ Digital Multimeter Showcase

 

 FEATURES

  • 600 V Cat III safety rating.
  • 50% bigger display with bright white backlight.
  • Over-voltage indicator.
  • Frequency and temperature measurement.
  • Voltage, resistance, continuity, capacitance.
  • Input terminal for ac and dc current measurements to 10 A current.
  • Diode test
  • Data hold.

 

SET INCLUDES

  • Fluke 17B+.
  • TL75 test leads with two caps.
  • 2 AA batteries.
  • User’s manual.

FLUKE 17B+ Digital Multimeter

Additional information

Accuracy Specifications

AC volts (40 Hz to 500Hz)¹

Range – 4.000 V, 40.00 V, 400.0 V, 1000 V
Resolution – 0.001 V, 0.01 V, 0.1 V, 1 V
Accuracy – 1.0% + 3

DC volts

Range – 4.000 V, 40.00 V, 400.0 V, 1000 V
Resolution – 0.001 V, 0.01 V, 0.1 V, 1 V
Accuracy – 0.5% + 3

AC millivolts

Range – 400.0 mV
Resolution – 0.1 mV
Accuracy – 3.0% + 3

DC millivolts

Range – 400.0 mV
Resolution – 0.1 mV
Accuracy – 1.0% + 10

Diode test²

Range – 2.000 V
Resolution – 0.001 V
Accuracy – 10%

Resistance (Ohms)

Range – 400.0 Ω, 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ
Resolution – 0.1 Ω, 0.001 kΩ, 0.01 kΩ, 0.1 kΩ, 0.001 MΩ, 0.01 MΩ
Accuracy – 0.5% + 3, 0.5% + 2, 0.5% + 2, 0.5% + 2, 0.5% + 2, 1.5% + 3

Capacitance³

Range – 40.00 nF, 400.0 nF, 4.000 μF, 40.00 μF, 400.0 μF, 1000 μF
Resolution – 0.01 nF, 0.1 nF, 0.001 μF, 0.01 μF, 0.1 μF, 1 μF
Accuracy – 2% + 5, 2% + 5, 5% + 5, 5% + 5, 5% + 5, 5% + 5

Frequency¹ Hz (10 Hz – 100 kHz)

Range – 50.00 Hz, 500.0 Hz, 5.000 kHz, 50.00 kHz, 100.0 kHz
Resolution – 0.01 Hz, 0.1 Hz, 0.001 kHz, 0.01 kHz, 0.1 kHz
Accuracy – 0.1% + 3

Duty Cycle¹

Range – 1% to 99%
Resolution – 0.1%
Accuracy – 1% typical⁴

AC current μA (40 Hz to 400 Hz)

Range – 400.0 μA, 4000 μA
Resolution – 0.1 μA, 1 μA
Accuracy – 1.5% + 3

AC current mA (40 Hz to 400 Hz)

Range – 40.00 mA, 400.0 mA
Resolution – 0.01 mA, 0.1 mA
Accuracy – 1.5% + 3

AC current A (40 Hz to 400 Hz)

Range – 4.000 A, 10.00 A
Resolution – 0.001 A, 0.01 A
Accuracy – 1.5% + 3

DC current μA

Range – 400.0 μA, 4000 μA
Resolution – 0.1 μA, 1 μA
Accuracy – 1.5% + 3

DC current mA

Range – 40.00 mA, 400.0 mA
Resolution – 0.01 mA, 0.1 mA
Accuracy – 1.5% + 3

DC current A

Range – 4.000 A, 10.00 A
Resolution – 0.001 A, 0.01 A
Accuracy – 1.5% + 3

Temperature - Accuracy

Range – 50 °C- 400 °C, 0 °C- 50 °C, -55 °C- 0 °C
Resolution – 0.1C
Accuracy – 2% ±1 °C, ±2 °C, 9% ±2 °C

Backlight

Yes

Accuracy Specifications Notes

1. All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2. Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
4. Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90%.

Overload protection

AC Volts – 1000 V¹
AC Millivolts – 400 mV
DC Volts – 1000 V¹
DC Millivolts – 400 mV

Input impedance (Nominal)

AC Volts – >10 MΩ <100 pF
AC Millivolts – >1MΩ, <100 pF
DC Volts – >10 MΩ <100 pF
DC Millivolts – >1MΩ, <100 pF

Common mode rejection ratio

AC Volts – 60 dB at dc, 50 Hz or 60 Hz
AC Millivolts – >80 dB at 50 Hz or 60 Hz
DC Volts – >100 dB at dc, 50 Hz or 60 Hz
DC Millivolts – >80 dB at 50 Hz or 60 Hz

Normal mode rejection ratio

AC Volts – N/A
AC Millivolts – N/A
DC Volts – >60 dB at 50 Hz or 60 Hz
DC Millivolts – N/A

Overload Protection Notes

1. 106 V Hz Max

General specifications

Maximum voltage between any terminal and earth ground

1000 V

Display (LCD)

4000 counts, updates 3/sec

Battery type

2 AA, NEDA 15A, IEC LR6

Battery life

500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)

General Temperature

Operating: 0 °C to 40 °C
Storage: -30 °C to 60 °C

Operating humidity

Non-condensing (<10°C) – ≤90% RH at 10 °C to 30 °C, ≤75% RH at 30 °C to 40 °C
40 MΩ range – ≤80% RH at 10 °C to 30 °C, ≤70% RH at 30 °C to 40 °C

General Altitude

Operating – 2000 m
Storage – 12,000 m

Temperature coefficient

0.1 X (specified accuracy) /°C (<18 °C or >28 °C)

Fuse protection for current inputs

440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.

Size (H x W x L)

183 x 91 x 49.5 mm

Weight

455 g

IP rating

IP 40

Safety

IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2

Electromagnetic environment

IEC 61326-1: Portable

Electromagnetic compatibility

Applies to use in Korea only

Electromagnetic compatibility notes

Class A equipment (industrial broadcasting and communication equipment)¹

1. This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.

Scope of Delivery

  • Fluke 17B+.
  • TL75 test leads with two caps.
  • 2 AA batteries.
  • User’s manual.

Product Warranty

The Fluke 17B+ carries a 1-year limited warranty against manufacture default. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Button Guide

Symbol Guide

Jack Guide

Display Guide

Safety Information

Safety Information

  • A Warning identifies conditions and procedures that are dangerous to the user.
  • To prevent possible electrical shock, fire, or personal injury: Carefully read all instructions.
  • Read all safety information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Use only correct measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Remove all probes, test leads, and accessories before the battery door is opened.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Remove the input signals before you clean the Product.
  • Have an approved technician repair the Product.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Use only specified replacement parts.
  • Use only specified replacement fuses.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not use in CAT III or CAT IV environments without the protective cap installed. The protective cap decreases the exposed probe metal to <4 mm. This decreases the possibility of arc flash from short circuits.
  • To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product to the circuit when you measure the current. Connect the Product in series with the circuit.
  • For safe operation and maintenance of the product, repair the Product before use if the batteries leak.

 

For additional safety information, visit the Fluke Safety Resource Center.