COMPACT. SAFE. RELIABLE

FLUKE 106 Palm Sized Digital Multimeter

AAA | 600V | 0-40°C | 200 HOURS | IP40

R2,090.00

FloatOr as low as R522.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK4367927

The Fluke 106 Palm-Sized Digital Multimeter is made to fit the way you work! It is designed to fit in the palm of your hand and go with you no matter where your job takes you. Review the product Data Sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

Fluke Range - Top Dog Tool ShopFluke 106 Manual

 

Reliable measurements time after time.

The FLUKE 106 Palm-Sized Multimeter is made to fit the way you work! Designed to fit in the palm of your hand and go with you no matter where your job takes you. Review the 106 data sheet for all electrical and technical specifications.

 

 

Fluke 106 Digital Multimeter Showcase

FEATURES

  • The 106 measures voltage, resistance, continuity, and capacitance.
  • Input terminal for ac and dc current measurements to 10 A and current
  • A data hold function which freezes the displayed measurement value for ease of reading.

 

SET INCLUDES

  • Fluke 106 Palm-sized Digital Multimeter.
  • Tl75 Hard Point Test Lead Set.
  • 2 AAA Batteries (Installed).
  • User’s Manual.

FLUKE 106 Palm-Sized Multimeter

Additional information

Accuracy Specifications

AC Volts* (40 Hz to 500Hz) - Range

6.000 V, 60.00 V, 600.0 V

AC Volts* (40 Hz to 500Hz) - Resolution

‎0.001 V, 0.01 V, 0.1 V

AC Volts* (40 Hz to 500Hz) - Accuracy

1.0 % + 3

DC Volts - Range

6.000 V, 60.00 V, 600.0 V

DC Volts - Resolution

0.001 V, 0.01 V, 0.1 V

DC Volts - Accuracy

0.5 % + 3

AC Millivolts - Range

600.0 mV

AC Millivolts - Resolution

0.1 mV

AC Millivolts - Accuracy

3.0 % + 3

Diode Test** - Range

2.000 V

Diode Test** - Resolution

0.001 V

Diode Test** - Accuracy

10 %

Resistance (Ohms) - Range

400.0 Ω, 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ

Resistance (Ohms) - Resolution

0.1 Ω, 0.001 kΩ, 0.01 kΩ, 0.1 kΩ, 0.001 MΩ, 0.01 MΩ

Resistance (Ohms) - Accuracy

0.5 % + 3, 0.5 % + 2, 0.5 % + 2, 0.5 % + 2, 0.5 % + 2, 1.5% + 3

Capacitance*** - Range

50.00 nF, 500.0 nF, 5.000 μF, 50.00 μF, 500.0 μF, 1000 μF

Capacitance*** - Resolution

0.01 nF, 0.1 nF, 0.001 μF, 0.01 μF, 0.1 μF, 1 μF

Capacitance*** - Accuracy

2 % + 5, 2 % + 5, 5 % + 5, 5 % + 5, 5 % + 5, 5 % + 5

Frequency Hz**** (10 Hz – 100 kHz) - Range

50.00 Hz, 500.0 Hz, 5.000 kHz, 50.00 kHz, 100.0 kHz

Frequency Hz**** (10 Hz – 100 kHz) - Resolution

0.01 Hz, 0.1 Hz, 0.001 kHz, 0.01 kHz, 0.1 kHz

Frequency Hz**** (10 Hz – 100 kHz) - Accuracy

N/A

Duty Cycle**** - Range

1 % to 99 %

Duty Cycle**** - Resolution

0.1 %

Duty Cycle**** - Accuracy

N/A

AC Current (40 Hz to 200 Hz) - Range

4.000 A, 10.00 A

AC Current (40 Hz to 200 Hz) - Resolution

0.001 A, 0.01 A

AC Current (40 Hz to 200 Hz) - Accuracy

1.5 % + 3

DC Current - Range

4.000 A, 10.00 A

DC Current - Resolution

0.001 A, 0.01 A

DC Current - Accuracy

1.5 % + 3

Accuracy Specification Notes

* All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
** Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
*** Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
**** All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.

Overload Protection - AC Volts

600 V*

Input Impedance (Nominal) - AC Volts

>10 MΩ <100 pF 2**

Common Mode Rejection Ratio - AC Volts

>60 dB at dc, 50 Hz or 60 Hz

Normal Mode Rejection Ratio - AC Volts

N/A

Overload Protection - \AC Millivolts

600 mV

Input Impedance (Nominal) - \AC Millivolts

>1M, <100 pF

Common Mode Rejection Ratio - \AC Millivolts

>80 dB at 50 Hz or 60 Hz

Normal Mode Rejection Ratio - \AC Millivolts

N/A

Overload Protection - DC Volts

600 V*

Input Impedance (Nominal) - DC Volts

>10 MΩ <100 pF

Common Mode Rejection Ratio - DC Volts

>100 dB at dc, 50 Hz or 60 Hz

Normal Mode Rejection Ratio - DC Volts

>60 dB at 50 Hz or 60 Hz

Overload Protection Notes

* 6 x 105 V Hz Max

Input Impedance Notes

** For mV (AC), input impedance is approximately 1 MΩ.

General Specifications

Maximum Voltage Between any Terminal and Earth Ground

600 V

Display (LCD)

6000 counts, updates 3/sec

Battery Type

2 AAA, NEDA 24A, IEC LR03

Battery Life

200 hours minimum

Temperature

Operating Temperature

0 °C to 40 °C

Storage Temperature

-30 °C to 60 °C

Relative Humidity

Operating Humidity

Non-condensing when <10°C
≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C

Operating Humidity, 40 MΩ Range

≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C

Altitude

Operating Altitude

2000 m

Storage Altitude

12,000 m

Temperature Coefficient

0.1 X (specified accuracy) /°C (<18 °C or >28 °C)

Fuse Protection for Current Inputs

11A, 1000V Fast Fuse, Fluke specified part only

Size (HxWxL)

142 mm x 69 mm x 28mm

Weight

200 g

IP Rating

IEC 60529: IP 40

Safety

IEC 61010-1: 600 V CAT III, Pollution Degree 2

Electromagnetic Environment

IEC 61326-1: Portable

Electromagnetic Compatibility

Applies to use in Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment)*

Electromagnetic Compatibility Notes

* This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes.

Scope of Delivery

  • Fluke 106 Palm-sized Digital Multimeter.
  • Tl75 Hard Point Test Lead Set.
  • 2 AAA Batteries (Installed).
  • User’s Manual.

Product Warranty

The Fluke 106 carries a 1-year limited warranty against manufacture default. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Button Guide

Symbol Guide

Jack Guide

Display Guide

Safety Information

Safety Information

  • A Warning identifies conditions and procedures that are dangerous to the user.
  • To prevent possible electrical shock, fire, or personal injury: Carefully read all instructions.
  • Read all safety information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Use only correct measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Remove all probes, test leads, and accessories before the battery door is opened.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Remove the input signals before you clean the Product.
  • Have an approved technician repair the Product.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Use only specified replacement parts.
  • Use only specified replacement fuses.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not use in CAT III or CAT IV environments without the protective cap installed. The protective cap decreases the exposed probe metal to <4 mm. This decreases the possibility of arc flash from short circuits.
  • To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product to the circuit when you measure the current. Connect the Product in series with the circuit.
  • For safe operation and maintenance of the product, repair the Product before use if the batteries leak.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.