COMPACT. SAFE. RELIABLE

FLUKE 107 Palm Sized Digital Multimeter

AAA | 600V | 0-40°C | 200 HOURS | IP40

R2,490.00

FloatOr as low as R622.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK4367966

The Fluke 107 Palm-Sized Multimeter is a compact, palm-size easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool; small enough to fit in a shirt pocket yet tough enough to withstand daily use, including a 1-meter drop test. Review the product Data Sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock: delivery in 1-3 working days

Description

Fluke Range - Top Dog ToolshopFluke 107 Manual

 

Reliable measurements time after time.

The Fluke 107 Palm-Sized Multimeter is a compact, palm-size easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool; small enough to fit in a shirt pocket yet tough enough to withstand daily use, including a 1-meter drop test.

For everyday applications where true-RMS accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time. With a CAT III 600 V safety rating, you don’t need to compromise safety. Review the 107 data sheet for all electrical and technical specifications.

 

 

Fluke 107 Digital Multimeter Showcase

FEATURES

  • Measures voltage, resistance, continuity, and capacitance.
  • Input terminal for ac and dc current measurements to 10 A and current.
  • A data hold function which freezes the displayed measurement value for ease of reading.
  • Work comfortably in darker environments due to the backlit display.
  • Diode test, plus frequency and duty cycle measurements.

 

TEST FUNCTIONS

  • AC and DC voltage.
  • AC and DC current.
  • Resistance.
  • Capacitance.
  • Diode.
  • Frequency and duty cycle.

 

SET INCLUDES

  • FLUKE 107 Palm-Sized Multimeter (CAT III Digital Multimeter).
  • TL75 Hard Point™ Test Lead Set.
  • Two AAA batteries (installed).
  • SmartStrap™ intelligent magnetic multi-purpose lanyard.

 

Additional information

Precision specifications

AC voltage (40 Hz to 500 Hz)* - Range

6.000 V, 60.00 V, 600.0 V

AC voltage (40 Hz to 500 Hz)* - Resolution

0.001 V, 0.01 V, 0.1 V

AC voltage* (40 Hz to 500 Hz) - Accuracy

1.0 % + 3

DC voltage - Range

6.000 V, 60.00 V, 600.0 V

DC voltage - Resolution

0.001 V, 0.01 V, 0.1 V

DC voltage - Accuracy

0.5 % + 3

Exchange millivolts - Range

600.0 mV

Exchange millivolts - Resolution

0.1 mV

Exchange millivolts - Accuracy

3.0 % + 3

Diode test** - Range

2.000 V

Diode test** - Resolution

0.001 V

Diode test** - Accuracy

10 %

Resistance (ohm) - Range

400.0 Ω, 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ

Resistance (ohm) - Resolution

0.1 Ω, 0.001 kΩ, 0.01 kΩ, 0.1 kΩ, 0.001 MΩ, 0.01 MΩ

Resistance (ohm) - Accuracy

0.5 % + 3, 0.5 % + 2, 0.5 % + 2, 0.5 % + 2, 0.5 % + 2, 1.5% + 3

Capacitor*** - Range

50.00 nF, 500.0 nF, 5.000 μF, 50.00 μF, 500.0 μF, 1000 μF

Capacitor*** - Resolution

0.01 nF, 0.1 nF, 0.001 μF, 0.01 μF, 0.1 μF, 1 μF

Capacitor*** - Accuracy

2 % + 5, 2 % + 5, 5 % + 5, 5 % + 5, 5 % + 5, 5 % + 5

Frequency**** Hz (10 Hz – 100 kHz) - Range

50.00 Hz, 500.0 Hz, 5.000 kHz, 50.00 kHz, 100.0 kHz

Frequency**** Hz (10 Hz – 100 kHz) - Resolution

0.01 Hz, 0.1 Hz, 0.001 kHz, 0.01 kHz, 0.1 kHz

Frequency**** Hz (10 Hz – 100 kHz) - Accuracy

0.1 % + 3

Duty cycle**** - Range

1 % to 99 %

Duty cycle**** - Resolution

0.10 %

Duty cycle**** - Accuracy

1 % typical case*****

AC current (40 Hz - 200 Hz) - Range

4.000 A, 10.00 A

AC current (40 Hz - 200 Hz) - Resolution

0.001 A, 0.01 A

AC current (40 Hz - 200 Hz) - Accuracy

1.5 % + 3

DC current - Range

4.000 A, 10.00 A

DC current - Resolution

0.001 A, 0.01 A

DC current - Accuracy

1.5 % + 3

Precision specification notes

* All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
** Typically, the open circuit test voltage is 2.0 V and the short circuit current is < 0.6 mA.
*** The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range).
**** All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.
***** Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%.

AC voltage - Overload protection

600 V*

AC voltage - Input impedance (nominal value)

>10 MΩ <100 pF**

AC voltage - Common mode rejection ratio

>60 dB at 50 Hz or 60 Hz at DC current

AC voltage - Normal mode rejection ratio

N/A

Exchange millivolts - Overload protection

600 mV

Exchange millivolts - Input impedance (nominal value)

>1M, <100 pF

Exchange millivolts - Common mode rejection ratio

>80 dB at 50 Hz or 60 Hz

Exchange millivolts - Normal mode rejection ratio

N/A

DC voltage - Overload protection

600 V*

DC voltage - Input impedance (nominal value)

>10 MΩ <100 pF

DC voltage - Common mode rejection ratio

>100 dB at 50 Hz or 60 Hz at DC current

DC voltage - Normal mode rejection ratio

>60 dB at 50 Hz or 60 Hz

Overload protection notes

* Up to 6 x 105 V Hz

Input impedance (nominal value) notes

** For medium voltage (alternating current), the input impedance is approximately 1 MΩ.

General technical indicators

The highest voltage applied to any terminal and ground

600 V

Display (LCD)

6000 counts, updated three times per second

Type of battery

Two AAA batteries (NEDA 24A, IEC LR03)

Battery life

At least 200 hours

Temperature

Operating temperature

0 °C to 40 °C

Storage temperature

-30 °C to 60 °C

Relative humidity

Working humidity

No condensation below 10 °C
≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C

Working humidity, 40 MΩ range

≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C

Altitude

Working elevation

2000 m

Storage altitude

12,000 m

Temperature coefficient

0.1 X (specified accuracy) / °C (<18 °C or >28 °C)

Current input fuse protection

11A, 1000V fast-melting type, must use Fluke designated parts

Volume (height x width x length)

142 mm x 69 mm x 28 mm

Weight

200 g

Protection level

IEC 60529: IP 40

Safety

IEC 61010-1: 600 V CAT III, pollution degree 2

Electromagnetic environment

IEC 61326-1: Portable

Electromagnetic compatibility

Applicable only in Korea. Class A equipment (industrial broadcasting and communication equipment)*

Electromagnetic compatibility notes

* This product meets the requirements of industrial (Class A) electromagnetic wave equipment, which should be noted by the seller or user. The device is suitable for use in a work environment, not a home environment.

Scope of Delivery

  • Fluke 107 Palm-sized, CAT III Digital Multimeter.
  • TL75 Hard Point™ Test Lead Set.
  • Two AAA batteries (installed).
  • SmartStrap™ intelligent magnetic multi-purpose lanyard.

Product Warranty

The Fluke 107 carries a 1-year limited warranty against manufacture default. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Button Guide

Symbol Guide

Jack Guide

Display Guide

Safety Information

Safety Information

  • A Warning identifies conditions and procedures that are dangerous to the user.
  • To prevent possible electrical shock, fire, or personal injury: Carefully read all instructions.
  • Read all safety information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Use only correct measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Remove all probes, test leads, and accessories before the battery door is opened.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Remove the input signals before you clean the Product.
  • Have an approved technician repair the Product.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Use only specified replacement parts.
  • Use only specified replacement fuses.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not use in CAT III or CAT IV environments without the protective cap installed. The protective cap decreases the exposed probe metal to <4 mm. This decreases the possibility of arc flash from short circuits.
  • To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product to the circuit when you measure the current. Connect the Product in series with the circuit.
  • For safe operation and maintenance of the product, repair the Product before use if the batteries leak.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

9PC HEX

Ball-End Key Set

Orders Over R6K

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.