EASY TO USE

FLUKE 302+ Digital Clamp Meter

AAA | 400A | CAT III 600 V | 400/600 VAC

R2,990.00

FloatOr as low as R747.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK4214747

The FLUKE 302+ Digital Clamp Meter is a compact, easy-to-use digital clamp meter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where True-RMS accuracy isn’t needed, the Fluke 302+ delivers reliable measurements time after time. Review the Fluke 302+ data sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Rugged, easy-to-use digital clamp meter.

The Fluke 302+ Digital Clamp Meter is a compact, easy-to-use digital clamp meter made to fit the way you work. The perfect first-pass troubleshooting tool, it is small enough to fit in a work bag and tough enough to withstand daily use, as well as being extremely simple to operate. For everyday applications, where True-RMS accuracy isn’t needed, the Fluke 302+ delivers reliable measurements time after time. Review the Fluke 302+ data sheet for all technical specifications.

 

 

FEATURES

  • Handle your everyday electrical maintenance with AC current measurements up to 400 A.
  • Comes with the TL75 Hard Point™ Test Lead Set
  • A convenient offering due to the test lead and probe in one unit with a variety of connections.
  • CAT IV 300 V/CAT III 600 V safety rating.
  • Recommended for general purpose measurements.
  • CAT II 1000 V, 10 A rating.
  • CAT IV 600 V, CAT III 1000 V only with protective cap.
  • Compact, making the use of clamp-type ammeter more flexible and simpler.
  • Measure AC current up to 400A with high accuracy of 1.8%.
  • 30 mm large jaw.
  • Backlit display.
  • Two-year warranty.

 

SET INCLUDES

  • FLUKE 302+ Digital Clamp Meter.
  • Fluke TL75 Hard Point™ Test Lead Set.
  • 2 AAA batteries (installed).
  • 2-year warranty.

FLUKE 302+ Digital Clamp Meter

Additional information

Technical Specifications

AC current

Range – 400.0 A
Accuracy – 1.8% ±5

AC voltage

Range – 400/600
Accuracy – 1.5% ±5

DC voltage

Range – 400/600
Accuracy – 1.5% ±5

DC mV range

N/A

Resistance

Range – 4000 Ω
Accuracy – 1% ±5

Continuity

≤ 70 Ω

Backlight display

Yes

Data hold

Yes

Size

H x W x D (mm) – 208 x 58.5 x 28
Jaw size – 30 mm

Safety rating

CAT III 600 V

Temperature

0 ~ 40 °C

Screen refresh rate

> 2 times / sec.

Test leads

TL75

Battery

2 AAA batteries

Warranty

2 years

Scope of Delivery

  • Fluke 302+ CAT III Digital Clamp Meter
  • Fluke TL75 Hard Point™ Test Lead Set
  • 2 AAA batteries (installed)
  • 2-year warranty

Product Warranty

The Fluke 302+ carries a 2-year limited warranty against manufacture defects. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Clamp Guide

Safety Information

Safety Information

  • A Warning identifies conditions and procedures that are dangerous to the user.
  • To prevent possible electrical shock, fire, or personal injury: Carefully read all instructions.
  • Read all safety information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Use only correct measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Remove all probes, test leads, and accessories before the battery door is opened.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Remove the input signals before you clean the Product.
  • Have an approved technician repair the Product.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Use only specified replacement parts.
  • Use only specified replacement fuses.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not use in CAT III or CAT IV environments without the protective cap installed. The protective cap decreases the exposed probe metal to <4 mm. This decreases the possibility of arc flash from short circuits.
  • To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product to the circuit when you measure the current. Connect the Product in series with the circuit.
  • For safe operation and maintenance of the product, repair the Product before use if the batteries leak.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.