Meets the needs of most industrial and residential temperature applications.
The FLUKE 80K-15 High Voltage Probe is designed to extend the voltage measuring capability of an AC/DC voltmeter to 15,000 volts peak AC or DC Overvoltage Category I. It is only suitable to make measurements on energy limited circuits within equipment. Examples include high voltage within televisions or photocopy machines. DO NOT use this probe to measure high voltages on power distribution systems. Review the Fluke 80K-15 data sheet for all technical specifications.
FEATURES
- Safety standards – IEC 1010-2-031:1993, Type B, 40 kV DC or peak AC, 28kV rms AC, Overvoltage Category I (voltage derived from limited energy transformer).
- Voltage range – 0 to 15kV DC or peak AC, 10kV rms AC
- Basic accuracy – DC +/- 2% 60Hz: +/- 5%
- Fluke 80K-15 High Voltage Probe Division ratio – 1000:1
- Input resistance – 1000 Megohm.
- Required meter input resistance – 10 Megohm.
COMPATIBLE PRODUCTS
- Fluke Digital Multimeters – Fluke 179, Fluke 87V MAX, Fluke 87V MAX E2, Fluke 175, 177, 179, Fluke 27 II, Fluke 28 II, Fluke 287, 289.
- Fluke mA Loop Calibrators – Fluke 787B, 789.