QUICK & EASY MEASUREMENTS

FLUKE T5-1000 Electrical Tester

12.9MM | 0-100A | 0-1000V | 1000Ω

R6,190.00

FloatOr as low as R1,547.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK659570

The T5-1000 Electrical Tester is a versatile troubleshooting tool to carry to every job site. Use it to check voltage, continuity, and current with one compact tool. the OpenJaw™ design allows for fast and easy current measurements without needing to make metallic contact, just slide a wire into the open fork. The continuity beeper offers quick go/no-go tests and resistance measurements to 1000 Ω. Review the Fluke T5-1000 data sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Voltage, Continuity and Current Tester.

The Fluke T5-1000 Electrical Tester is a versatile troubleshooting tool to carry to every job site. Use it to check voltage, continuity, and current with one compact tool. the OpenJaw™ design allows for fast and easy current measurements without needing to make metallic contact, just slide a wire into the open fork. The continuity beeper offers quick go/no-go tests and resistance measurements to 1000 Ω. Review the Fluke T5-1000 data sheet for all technical specifications.

 

 

FEATURES

  • OpenJaw™ design: measure current without breaking the circuit.
  • The tester automatically selects AC or DC voltage, up to 1000 V.
  • Work in tight spaces with detachable Slim Reach probe tips.
  • Hands free working when using the test lead holder to make the meter an “extended handle” for the probe.
  • A CAT III 1000V, CAT IV 600 V rating
  • T5-1000 Electrical Tester is able to withstand a 3m drop.
  • Auto-off mode to conserve battery life
  • Fits into an optional holster that attaches to a belt and neatly stows test leads.

 

SET INCLUDES

  • Fluke T5-1000 Electrical Tester.
  • 4 mm detachable probes.
  • Quick Reference Guide.

 

Additional information

Specifications

‎‎‎

Jaw opening

12.9 mm (0.5 in)

Max wire size

1/0 THHN Cable

Current range AC rms

0 to 100.0 A

Accuracy AC current (50/60 Hz)

3% ± 3 counts

AC response

Averaging

Voltage range AC/DC

0 to 1000 V

Voltage accuracy

AC – 1.5% ± 2 counts
DC – 1% ± 1 count

Resistance range

0 to 1000 Ω

Continuity beeper threshold

On at < 25 Ω, off at > 400 Ω

Volts indicator LED threshold

Guaranteed on by 30 V AC

Environmental Specifications

‎‎‎

Operating temperature

-10°C to 50°C

Storage temperature

-30°C to 60°C

Humidity (without condensation)

0% to 95% (5°C to 30°C);
0% to 75% (30°C to 40°C);
0% to 45% (40°C to 50°C)

Dust/water resistance

Yes

Operating altitude

2000 meters max

Temperature coefficient

0.1 x (specified accuracy)/°C (< 18°C or> 28°C)

Safety Specifications

‎‎‎

Measurement Category

IEC 61010-2-032, IEC61010-2-033: CAT IV 600 V / CAT III 1000 V, 100 A AC

Agency approvals

CSA, TUV

Maximum voltage

1000 V between any terminal and earth ground

Mechanical and General Specifications

‎‎‎

Size

30.5 x 51 x 203 mm

Weight

300 g

Warranty

Two-years

Battery life

200 hour zinc chloride, 400 hour alkaline

Battery type

2 x AA

Low battery indicator

Yes

Current sensor opening

12.9 mm

Scope of Delivery

  • Fluke T5-1000 Electrical Tester.
  • 4 mm detachable probes.
  • Quick Reference Guide.

Product Warranty

The Fluke T5-1000 carries a 2-year limited warranty against manufacture defects. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Safety Information

Safety Information

A Warning identifies conditions and procedures that are dangerous to the user.To prevent possible electrical shock, fire, or personal injury:

  • Read all safety Information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
    Carefully read all instructions.
  • Do not use and disable the Product if it is damaged. Protection may be impaired.
  • The battery door must be closed and locked before you operate the Product.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the
    insulation around the terminals.
  • Comply with local and national safety codes. Use personal protective equipment (approved rubber gloves, face protection, and flame-resistant clothes) to prevent shock and arc blast injury where hazardous live conductors are exposed.
  • Measure a known voltage first to make sure that the product operates correctly.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not apply more than the rated voltage, as marked on the Product, between terminals or between any terminal and earth ground.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Clean the case with a damp cloth and detergent. Do not use abrasives or solvents.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  •  Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Use the correct terminals, function, and range for measurements.
  • Hold the Product behind the tactile barrier.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Use only current probes, test leads, and adapters supplied with the Product.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Repair the Product before use if the battery leaks.
  • Be sure that the battery polarity is correct to prevent battery leakage.
  • Do not operate the Product with covers removed or the case open. Hazardous voltage exposure is possible.
  • Use only specified replacement parts.
  • Have an approved technician repair the Product.
  • Disconnect power and discharge all high-voltage capacitors before you measure resistance, continuity, capacitance, or a diode junction.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.