VISUAL CONTINUITY™

FLUKE T6-1000PRO/EU Electrical Tester With Field Sense Pro Kit

AA | 1-1000V ACDC | 0.1-200A | 1-100Ω

R9,930.00

FloatOr as low as R2,482.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK5134758

The T6-1000 PRO Electrical Tester measures voltage up to 1000 V ac and current up to 200 A ac, all through the open fork and without test lead contact to live voltage. Connect the black lead to ground with the included heavy-duty alligator clip, slide the wire into the open fork and see both voltage and current at the same time on wires up to AWG 4/0 (120 mm2), carrying as much as 200 A and 1000 V ac. Review the Fluke T6-1000PRO data sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Voltage and current on one screen.

The Fluke T6-1000 Pro Electrical Tester measures voltage up to 1000 V ac and current up to 200 A ac, all through the open fork and without test lead contact to live voltage. Connect the black lead to ground with the included heavy-duty alligator clip, slide the wire into the open fork and see both voltage and current at the same time on wires up to AWG 4/0 (120 mm2), carrying as much as 200 A and 1000 V ac. Review the Fluke T61000PRO data sheet for all technical specifications.

 

 

FEATURES

  • Save time by seeing voltage and current measurements at the same time.
  • Visual Continuity™ – the screen automatically turns green for continuity, perfect when it’s too loud to hear the beeper.
  • FieldSense™ technology for ac voltage, current and frequency, all without making electrical contact to live voltage.
  • True-RMS for accurate voltage and current measurements, even when measuring complex signals.
  • Measures 1 to 1000 V AC or DC as well as 0.1 to 200 A AC.
  • Resistance measurements of 1 Ω to 100 kΩ.
  • Frequency measurement of 45 Hz to 66 Hz through the open fork.
  • Jaw opening of 17.8 mm.
  • HOLD button temporarily freezes the screen for easy viewing.
  • Easy to read display with backlight.
  • Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation.

 

SET INCLUDES

  • Fluke T6-1000 Pro Electrical Tester.
  • Attached test leads with removable 4 mm probe caps.
  • Black AC285 SureGrip™ alligator clip.
  • H-T6 holster.
  • User documentation.

 

Additional information

Function

‎‎‎

FieldSense AC voltage

Requires test leads – No
Range – 1000 V
Resolution – 1 V
Accuracy – ±(3 % + 3 counts) 45 Hz – 66 Hz⁽¹⁾⁽²⁾

FieldSense AC current

Requires test leads – No
Range – 200.0 A
Resolution – 0.1 A
Accuracy – ±(3 % + 3 counts) 45 Hz – 66 Hz

FieldSense frequency (Hz)

Requires test leads – No
Range – 45 Hz – 66 Hz
Resolution – 1 Hz
Accuracy – ±(1 % + 2 counts)

Volts AC

Requires test leads – Yes
Range – 1000 V
Resolution – 1 V
Accuracy – ±(1.5 % + 2 counts) 45 Hz – 66 Hz

Volts DC

Requires test leads – Yes
Range – 1000 V
Resolution – 1 V
Accuracy – ±(1 % + 2 counts)

Resistance

Requires test leads (all ranges) – Yes
Range – 2000 Ω
Resolution – 1 Ω
Range – 20.00 kΩ
Resolution – 0.01 kΩ
Range – 100.0 kΩ
Resolution – 0.1 kΩ
Accuracy (all ranges) – ±(1 % + 2 counts)

Function notes

Accuracy¹: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, RMS responding.

Accuracy²: FieldSense specified from 16V to 1000V.

General Specifications

‎‎‎

Calibration

1-year calibration cycle

Dimensions

61 mm x 259 mm x 43 mm

Weight

0.35 kg (0.78 lb)

Fork opening

17.8 mm (0.7”)

Temperature

Operating: -10 °C to +50 °C (14 °F to 122 °F)
Storage: -30 °C to +60 °C (-22 °F to +140 °F)

Altitude

Operating: 2,000 m (6,562 feet)
Storage: 10,000 m (32,808 feet)

Relative Humidity

0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F)
0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F)
0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F)

Battery

Type: 2x AA (IEC LR6)
Life: 360 hour continuous, typical is 200 hour using the FieldSense function

Temperature coefficient

0.1 x (specified accuracy) / °C for <18°C or >28 °C (< 64.4 °F or > 82.4 °F)

Safety

General Measurement: IEC 61010-1: Pollution Degree 2
T6-1000 PRO: IEC 61010-2-032: CAT IV 600 V / CAT III 1000 V

Electromagnetic Compatibility

IEC/EN 61326-1: Portable

Scope of Delivery

  • Fluke T6-1000 Pro Electrical Tester.
  • Attached test leads with removable 4 mm probe caps.
  • Black AC285 SureGrip™ alligator clip.
  • H-T6 holster.
  • User documentation.

 

Product Warranty

The Fluke T6-1000 carries a 2-year limited warranty against manufacture defects. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Safety Sheet

Safety Information

A Warning identifies conditions and procedures that are dangerous to the user. To prevent possible electrical shock, fire, or personal injury:

  • Read all safety information before you use the Product.
  • Carefully read all instructions.
  • Do not alter the Product and use only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
    Comply with local and national safety codes. Use personal protective equipment (approved rubber gloves, face protection, and flame-resistant clothes) to prevent shock and arc blast injury where hazardous live conductors are exposed.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • T6-600/T6-1000: Examine the battery door decal for damage to this insulator. Look for any cracks, holes, or evidence of delamination. This insulator houses a laminated foil that provides a capacitive current path for the FieldSense function. This insulator provides a means of protection against electric shock when the COM probe test lead (black) is installed into the back case
  • The battery door must be closed and locked before you operate the Product.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation or exposed metal. Check test lead continuity.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Use the correct terminals, function, and range for measurements.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Keep fingers behind the finger guards on the probes.
  • Hold the Product behind the tactile barrier. See the Quick Reference Guide for this Product.
  • T6-600/T6-1000: To use the FieldSense Ground Contact, make sure the – test probe (BLACK) is stowed in the storage location in the back case before a FieldSense measurement. See the Quick Reference Guide for this Product.
  • Disconnect power and discharge all high-voltage capacitors before you measure resistance or continuity.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Do not operate the Product with covers removed or the case open. Hazardous voltage exposure is possible.
  • Have an approved technician repair the Product.
  • Use only specified replacement parts.

For safe operation and maintenance of the Product:

  • Remove batteries to prevent battery leakage and damage to the Product if it is not used for an extended period.
  • Repair the Product before use if the battery leaks.
  • Be sure that the battery polarity is correct to prevent battery leakage.
  • Clean the case with a damp cloth and detergent. Do not use abrasives or solvents.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.