ELECTRICAL TESTERS. THERMOMETER

FLUKE T6-600 With 62MAX+ 1AC Voltage Detector & C60 Softcase

600V | 200A | -30°C to 650°C | 12:1 | 90-1000 V

R11,890.00

FloatOr as low as R2,972.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK4910524

The Fluke T6-600/62Max+/1AC Kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use electrical test tools to find out more about the problem. Review the Fluke T6-600, 62Max+, and 1AC II product data sheets for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Three powerful testing tools in one package.

The Fluke T6-600/62Max+/1AC Kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use electrical test tools to find out more about the problem. The Fluke T6-600 Electrical Tester with FieldSense™ technology, lets you quickly and safely take measurements by sliding the open fork over a conductor, without the need for test leads.

The Fluke 62 Max+ IR Thermometer delivers the accuracy you need in an extremely rugged package. Just point, shoot and read the temperature of many types of equipment. The portable 1AC II non-contact voltage tester from Fluke is easy to use – just touch the tip to a terminal strip, outlet, or supply cord. When the tip glows red and the unit beeps, you know there’s voltage present. Review the Fluke T6-600, 62Max+, and 1AC II product data sheets for all technical specifications.

 

FLUKE T6-600 FEATURES

  • Included in the Fluke T6-600/62Max+/1AC Kit.
  • Measure true RMS voltage and current from 0 to 200 A AC or 1 to 600 V AC or DC without touching a live wire.
  • Gather resistance measurements from 1 Ω to 2000 Ω.
  • See your work in dark environments due to the easy-to-read backlit display.
  • Keep your most recent measurement on the screen with the HOLD button for easy viewing.
  • Troubleshoot all power supply measurements at-a-glance.
  • See AC voltage and current values without test leads.
  • The T6-600 also accepts an optional Fluke TPAK Magnetic Meter Hanger for convenient operation.
  • FieldSense™ technology detects an electrical field, which interacts with a reference signal created by the T6 tester, which shows the measurement value on the tester’s display.

 

 

FLUKE 62 MAX+ FEATURES

  • Extremely rugged – 3-meter drop tested, IP54 for dust and moisture.
  • Precise dual-lasers for more accurate, repeatable measurements.
  • Provides up to a 12:1 Distance to spot ratio.
  • Rapid detection of measurements outside the limits due to the high and low alarm indicators.
  • Displays Min/Max/Avg/Dif.
  • The minimum, maximum or average temperature, or the difference between two measurements.
  • Easy to read, even in dark areas due to the large backlit display.

 

 

FLUKE 1AC II FEATURES

  • Be aware of voltage easily – the tip glows red and a beeper sounds when voltage is detected (can be disabled).
  • Continuous self-test so you always know it’s working.
  • Voltage detection range for wide application use – 90 V to 1000 V AC or 200 V to 1000 V AC.
  • Audible/Silent mode for added convenience.
  • Rated to CAT IV 1000 V for added protection.
  • CE and CSA approved.

Additional information

Fluke T6-600 Electrical Tester

‎‎‎

Measurement Specifications

‎‎‎

FieldSense AC voltage true-RMS

Requires test leads – No
Range – 200.0 A
Resolution – 1 V
Accuracy¹ – ±(3% + 3 counts) 45 Hz – 66 Hz⁽²⁾⁽³⁾

FieldSense AC current true-RMS

Requires test leads – No
Range – 200.0 A
Resolution – 0.1 A
Accuracy¹ – ±(3% + 3 counts) 45 Hz – 66 Hz

FieldSense frequency (Hz)

Requires test leads – No
Range –
Resolution – 1 Hz
Accuracy¹ – ±(1% + 2 counts)⁽³⁾

Volts AC true-RMS

Requires test leads – Yes
Range – 600 V
Resolution – 1 V
Accuracy¹ – ±(1.5% + 2 counts) 45 Hz – 66 Hz

Volts DC

Requires test leads – Yes
Range – 600 V
Resolution – 1 V
Accuracy¹ – ±(1% + 2 counts)

Resistance

Requires test leads – Yes
Range – 2000 Ω
Resolution – 1 Ω
Accuracy¹ – ±(1% + 2 counts)

Notes

Accuracy¹: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.

Accuracy²: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.

Accuracy³: FieldSense is specified from 16 V to 100 % of range.

General Specifications

‎‎‎

Calibration

1-year calibration cycle

Dimensions

61.1 x 259.3 x 43.8 mm

Jaw opening

17.8 mm

Weight

0.35 kg (0.78 lb)

Temperature

Operating: -10 °C to +50 °C
Storage: -30 °C to +60 °C

Altitude

Operating – 2,000 m
Storage – 10,000 m

Relative Humidity

0% to 90%, 5 °C to 30 °C
0% to 75%, 30°C to 40 °C
0% to 45%, 40°C to 50 °C

Battery Type and Life

2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense

Temperature coefficient

0.1 x (specified accuracy) / °C for <18°C or >28 °C
(< 64.4 °F or > 82.4 °F)

Safety

IEC/EN 61010-1: Pollution Degree 2

Electromagnetic Environment

IEC/EN 61326-1: Portable

Fluke 62 MAX+ IR Thermometer

‎‎‎

62 MAX+ Specifications

#none

Temperature range

-30°C to 650°C (-22°F to 1202°F)

Accuracy

±1.0°C or ±1.0% of reading, whichever is greater
-10°C to 0°C: ±2.0
-30°C to -10°C: ±3.0

Response time (95%)

< 500 ms (95% of reading)

Spectral response

8 to 14 microns

Emissivity

0.10 to 1.00

Optical resolution

12:1 (calculated at 90% energy)

Display resolution

0.1°C (0.2°F)

Repeatability of readings

±0.5% of reading or <±0.5°C (1°F), whichever is greater

Power

AA battery

Battery life

8 hours with laser and backlight on

62 MAX+ Physical Specifications

‎‎‎

62 MAX+ Weight

255 g (8.99 oz)

62 MAX+ Size

175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)

62 MAX+ Operating temperature

0°C to 50°C (32°F to 122°F)

62 MAX+ Storage temperature

-20°C to 60°C (-4°F to 140°F), (without battery)

62 MAX+ Operating humidity

10% to 90% RH non-condensing at 30°C (86°F)

62 MAX+ Operating altitude

2000 meters above mean sea level

62 MAX+ Storage altitude

12,000 meters above mean sea level

62 MAX+ IP rating

IP 54 per IEC 60529

62 MAX+ Drop test

3 meters

62 MAX+ Vibration and shock

IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms

62 MAX+ Electromagnetic compliance

IEC 61326-1: Portable electromagnetic equipment

62 MAX+ Safety

IEC 61010-1: Pollution degree 2
IEC 60825-1: Class 2

Fluke 1AC II Non-Contact Voltage Tester

‎‎‎

Fluke 1AC II Specifications

‎‎‎

Fluke 1AC II Operating Principles

Senses the steady state electrostatic field produced by AC voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage.

1AC II Voltage sensing ranges

Nominally, 90 V AC to 1000 V AC

1AC II Detector tip style

Flat-tip

1AC II Light source

One high intensity red LED

1AC II Safety

IEC 61010-1: Pollution Degree 2, IEC 61010-2-030: CAT IV 1000 V

1AC II EMC

IEC 61326-1: Portable

1AC II IP Rating

IP 40

1AC II Operating Temperature

-10°C to 50°C (-14°F to 122°F)

1AC II Operating Humidity Ranges

0% to 95% (0°C to 30°C)
0% to 75% (30°C to 40°C)
0% to 45% (40 to 55°C)

1AC II Operating Altitude

3000 m

1AC II Cleaning

Clean with damp cloth

1AC II Batteries

2 AAA alkaline batteries included

1AC II Battery Life

Typical battery life of greater than 1 year

1AC II Warranty Period

Two years

1AC II Notes

Product does not respond to random electrostatic discharge.

Scope of Delivery

  • Fluke T6-600 Electrical Tester.
  • Attached test leads with removable 4 mm probe caps.
  • 62 MAX+ Handheld Infrared Laser Thermometer.
  • Fluke 1AC II Non-Contact Voltage Tester.
  • User documentation.

Product Warranty - T6-600

The Fluke T6-600 carries a 2-year limited warranty against manufacture defects. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Product Warranty - 62 Max+

The Fluke 62 Max+ carries a 3-year limited warranty against manufacture defects. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Product Warranty - 1AC II

The Fluke 1AC II Non-Contact Voltage Tester carries a 2-year limited warranty against manufacture default. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Safety Information

Safety Information

A Warning identifies conditions and procedures that are dangerous to the user. To prevent possible electrical shock, fire, or personal injury:

  • Read all safety Information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
    Carefully read all instructions.
  • Do not use and disable the Product if it is damaged. Protection may be impaired.
  • The battery door must be closed and locked before you operate the Product.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the
    insulation around the terminals.
  • Comply with local and national safety codes. Use personal protective equipment (approved rubber gloves, face protection, and flame-resistant clothes) to prevent shock and arc blast injury where hazardous live conductors are exposed.
  • Measure a known voltage first to make sure that the product operates correctly.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not apply more than the rated voltage, as marked on the Product, between terminals or between any terminal and earth ground.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Clean the case with a damp cloth and detergent. Do not use abrasives or solvents.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  •  Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Use the correct terminals, function, and range for measurements.
  • Hold the Product behind the tactile barrier.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Use only current probes, test leads, and adapters supplied with the Product.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Repair the Product before use if the battery leaks.
  • Be sure that the battery polarity is correct to prevent battery leakage.
  • Do not operate the Product with covers removed or the case open. Hazardous voltage exposure is possible.
  • Use only specified replacement parts.
  • Have an approved technician repair the Product.
  • Disconnect power and discharge all high-voltage capacitors before you measure resistance, continuity, capacitance, or a diode junction.

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.