TEMPERATURE & MICROAMPS

FLUKE 116 True-RMS HVAC Multimeter

9V | 600V | 400°C | CAT III 600 V | 400 HOURS

R7,890.00

FloatOr as low as R1,972.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK2583601

The Fluke 116 True-RMS HVAC Multimeter was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, as well as a built-in thermometer to measure temperatures up to 400°C (752°F) with microamps to test flame sensors. Review the Fluke 116 data sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Compact true-rms meter for HVAC troubleshooting .

The Fluke 116 True-RMS HVAC Multimeter was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, as well as temperature measurements up to 400°C (752°F) with the built-in thermometer. The Fluke 116 digital multimeter also measures resistance, continuity, frequency, and capacitance. Review the Fluke 116 data sheet for all technical specifications.

 

Fluke 116 True-RMS HVAC Multimeter Showcase

 

FEATURES

  • Digital multimeter designed specifically for HVAC professionals.
  • Includes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F).
  • Provides microamps to test flame sensors.
  • Features low input impedance to help prevent false readings due to ghost voltage.
  • Ideal for working in poorly lit areas due to the large white LED backlight.
  • Measures resistance, continuity, frequency, and capacitance.
  • Easy storage as a result of the holster with probe holders.
  • Provides Min/Max average to record signal fluctuations.
  • One-handed operation due to the compact ergonomic design.
  • Fits into an optional ToolPak™ magnetic hanger for hands-free operation.
  • CAT III 600 V safety rated for HVAC technicians, and building maintenance.

 

SET INCLUDES

  • Fluke 116 Digital Multimeter.
  • (1 pair) 4 mm silicone test lead set.
  • 80BK Integrated Temperature probe.
  • Holster.
  • Installed 9 V battery.
  • Quick reference guide.

 

Additional information

Specifications

Maximum voltage between any terminal and earth ground

600 V

Safety

IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V

Display

Digital: 6,000 counts, updates 4 per second

Bar graph

33 segments, updates 32 per second

Operating temperature

-10°C to + 50°C

Storage temperature

-40°C to + 60°C

Battery type

9 volt Alkaline, IEC 6LR61

Battery life

400 hours typical, without backlight

Accuracy Specifications

DC millivolts

Range/resolution – 600.0 mV / 0.1 mV
Accuracy ± – 0.5% + 2
([% of reading] + [counts])

DC volts

Range/resolution – 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.00 V / 0.1 V
Accuracy ± – 0.5% + 2
([% of reading] + [counts])

Auto volts

Range/resolution – 600.0 V / 0.1 V
Accuracy – 2.0% + 3 (DC, 45 Hz to 500 Hz), 4.0% + 3 (500 Hz to 1 kHz)

AC millivolts* True RMS

Range/resolution – 600.0 mV / 0.1 mV
Accuracy – 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)

AC volts* True RMS

Range/resolution – 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.0 V / 0.1 V
Accuracy – 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)

Continuity

Range/resolution – 600 Ω / 1 Ω
Accuracy Beeper on – < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.

Ohms

Range/resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9% + 1
Range/Resolution 40.00 MΩ / 0.01 MΩ
Accuracy 5% + 2

Diode Test

Range/resolution – 2.00 V / 0.001 V
Accuracy – 0.9% + 2

Capacitance

Range/resolution – 1000 nF / 1 nF, 10.00 μF / 0.01 μF, 100.0 μF / 0.1 μF, 9999 μF / 1 μF, 100 μF to 1000 μF
Accuracy – 1.9% + 2
Range/resolution – > 1000 μF
Accuracy – 5% + 20%

Lo-Z Capacitance

Range – 1 nF to 500 μF
Accuracy – 10% + 2 typical

Temperature² (Type-K thermocouple)

Range/resolution: -40°C to 400°C / 0.1°C
Accuracy – 1% + 10**
Range/resolution: -40°F to 752°F / 0.2°F
Accuracy – 1% + 18**

AC μA true-rms (45 Hz to 500 Hz)

Range/resolution – 600.0 μA / 0.1 μA
Accuracy – 1.5% + 3

DC μamps

Range/resolution – 600.0 μA / 0.1 μA
Accuracy – 1.0% + 2

Hz (V or A input)**

Range/resolution – 99.99 Hz / 0.01 Hz, 999.9 Hz / 0.1 Hz, 9.999 kHz / 0.001 Hz, 50.00 kHz / 0.01 Hz
Accuracy – 0.1% + 2

Accuracy Specification notes

** – All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
** – Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
*** – Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
**** – Temperature Range/Resolution: -40°F to 752°F / 0.2°F.

Mechanical and General Specifications

Size

167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)

Weight

550 g

Product Warranty

The Fluke 116 carries a 3-year warranty against manufacture defects. This warranty does not cover fuses, disposable batteries, damage from neglect, misuse, contamination, alteration, accident or abnormal conditions of operation or handling, including failures caused by use outside of the product’s specifications, or normal wear and tear of mechanical components.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Button Guide

Symbol Guide

Jack Guide

Display Guide

Safety Information

Safety Information

  • A Warning identifies conditions and procedures that are dangerous to the user.
  • To prevent possible electrical shock, fire, or personal injury: Carefully read all instructions.
  • Read all safety information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Use only correct measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Remove all probes, test leads, and accessories before the battery door is opened.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Remove the input signals before you clean the Product.
  • Have an approved technician repair the Product.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Use only specified replacement parts.
  • Use only specified replacement fuses.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not use in CAT III or CAT IV environments without the protective cap installed. The protective cap decreases the exposed probe metal to <4 mm. This decreases the possibility of arc flash from short circuits.
  • To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product to the circuit when you measure the current. Connect the Product in series with the circuit.
  • For safe operation and maintenance of the product, repair the Product before use if the batteries leak.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.