LI-ION

FLUKE 279FC True-RMS Thermal Multimeter with iFLEX Kit

1000V | 2500A | 102 x 77 | 8HZ | 0.793KG

R38,580.00

FloatOr as low as R9,645.00 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK4684050

The Fluke 279FC True-RMS Thermal Multimeter is a full-featured multimeter with a built-in thermal imager that reveals hot spots that may indicate electrical issues quickly and safely. Thermal imaging multimeters are a first-line troubleshooting tool for electrical equipment that can check hot spots on high-voltage equipment and transformers, as well as detecting heating of fuses, wires, insulators, connectors, splices and switches. Review the Fluke 279FC data sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Find, repair, validate and report electrical issues.

The Fluke 279FC True-RMS Thermal Multimeter is a full-featured multimeter with a built-in thermal imager that reveals hot spots that may indicate electrical issues quickly and safely. Thermal imaging multimeters are a first-line troubleshooting tool for electrical equipment that can check hot spots on high-voltage equipment and transformers, as well as detecting heating of fuses, wires, insulators, connectors, splices and switches. Review the Fluke 279FC data sheet for all technical specifications.

 

 

 FEATURES
  • In addition to being a full-featured electrical multimeter, the 279 includes a built-in thermal imager.
  • True-RMS AC voltage and current for measuring non-linear signals.
  • 15 measurement functions including voltage ac and dc, resistance, continuity, capacitance, diode test, Min/Max/Avg, current ac as well as frequency with included iFlex current probe.
  • Low-pass filter for troubleshooting adjustable speed drives.
  • Transmit results wirelessly to a smartphone due to the built-in Fluke Connect® capability.
  • iFlex expands your measurement capabilities – get into tight, hard-to-reach spaces for current measurement (up to 2500 A ac).
  • Save measurements and images while communicating wirelessly with a smartphone up to 20 feet / 6.1 m away (no obstructions).
  • The Colour LCD screen in addition to the 102 x 77 image resolution offers immediate visual cues of hot, potentially troublesome areas.
  • A rechargeable lithium-ion battery allows for a full work day (10+ hours) under normal conditions, therefore, a second battery option means you will always have a battery ready to install.
  • Auto power off to save battery power.
  • Increased protection due to the double insulation with raised rubber holster
  • Safety rated CAT III 1000 V, CAT IV 600 V
  • Designed for durability, built to withstand a 1 m (3 ft) drop,
  • Increased productivity as a result Two-in-one function of the multimeter.

 

SET INCLUDES

  • 279 FC TRMS Thermal Multimeter.
  • 45.72 cm iFlex Flexible Current Probe.
  • TL175 Test Leads.
  • Rechargeable Lithium Ion Battery and Charger.
  • Soft Carrying Case.
  • Hanging strap.

FLUKE 279FC True-RMS Thermal Multimeter

 

Additional information

Digital Multi Meter Specifications

Basic DC accuracy

0.09%

Bandwidth

1% 45 Hz to 65 Hz, full time low pass filter

Voltage

AC/DC 1000 V

Current AC

2500 A with included iFlex Flexible Current Probe

Resistance

50 MΩ

Frequency

100 kHz

Capacitance

9,999 µF

Continuity with beeper

Yes

Diode test

Yes

Min/Max recording

Yes

Display Hold

Yes

Infrared Camera

Infrared resolution

102 x 77

Image capture frequency

8 Hz

Field of View

36° (w) x 27° (h)

NETD

≤200 mK

Infrared spectral band

7.5 to 14 microns

Center point

Yes (with center point temp)

Focus mechanism

Fixed focus

Temperature Range (selectable °C and °F)

-10 °C to 200 °C (14 °F to 392 °F) Accuracy: ±5 °C (9 °F) or (±5% as tested)

Emissivity

0.95 fixed

Background compensation

20°C fixed

Memory storage

Approximately 100 images (internal)

File format

Non-radiometric .is2

General specifications

Battery type

Rechargeable lithium-ion battery (charge time: 4.5 hours)

Operating temperature

-10 °C to 50 °C (14 °F to 122 °F)

Storage temperature

-20 ºC to 60 ºC (-4 °F to 140 °F)

Relative humidity

0% to 90% (0 °C to 35 °C) (32 °F to 95 °F)
0% to 75% (35 °C to 40 °C) (95 °F to 104 °F)
0% to 45% (40 °C to 50 °C) (104 °F to 122 °F)

Altitude

2,000 meters (6,561 feet)

Temperature coefficient

Add 0.1 x specified accuracy for each °C above 28 °C or below 18 °C (°F above 82 °F or below 64° F)

Ingress Protection

(IP) IP40 (non-operating)

Wireless frequency

2.4 GHz ISM Band, 20 meter range

Certifications

CE, CSA, FCC

Safety compliance

IEC 61010-1: Pollution degree 2; IEC 61010-2-033: CAT III 1000 V/CAT IV 600 V

EMC

EN 61326-1:2012

Size

215.9 x 93.9 x 57.1 mm (8.5 x 3.7 x 2.25 in)

Weight

0.793 kg (1.75 lb)

Warranty

Limited three-year warranty

Scope of Delivery

  • 279 FC Thermal Multimeter
  • 45.72 cm (18 in) iFlex flexible current probe
  • (1 pair) TL175 test leads
  • Rechargeable lithium-ion battery and charger
  • Soft carrying case
  • Hanging strap
  • Quick reference guide

Product Warranty

The FLUKE 279FC carries a 3-year limited warranty against manufacture default. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Button Guide

Symbol Guide

Jack Guide

Display Guide

Safety Information

Safety Information

  • A Warning identifies conditions and procedures that are dangerous to the user.
  • To prevent possible electrical shock, fire, or personal injury: Carefully read all instructions.
  • Read all safety information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Use only correct measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Remove all probes, test leads, and accessories before the battery door is opened.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Remove the input signals before you clean the Product.
  • Have an approved technician repair the Product.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Use only specified replacement parts.
  • Use only specified replacement fuses.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not use in CAT III or CAT IV environments without the protective cap installed. The protective cap decreases the exposed probe metal to <4 mm. This decreases the possibility of arc flash from short circuits.
  • To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product to the circuit when you measure the current. Connect the Product in series with the circuit.
  • For safe operation and maintenance of the product, repair the Product before use if the batteries leak.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
1
Hi & welcome to Top Dog WhatsApp Support. We are available weekdays from 8am to 5pm.

How can we be of assistance today?