PACK OF FIVE

FLUKE 2AC Voltage Tester 5-Pack

90-1000VAC | CAT IV 1000 V

R5,190.00

FloatOr as low as R1,297.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK3807937

The Fluke 2AC Voltage Tester is ideal when you require multiple voltage testers for each member of your team and is the latest addition to the VoltAlert™ AC non-contact voltage tester family. The tip of the pocket-sized tester will glow red when within close proximity of an outlet, terminal strip, or power cord where voltage is present. The 2 AC is always on, with a battery check function to make sure the tester is working properly. Review the Fluke 2AC data sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Always on for faster, safer voltage testing.

The Fluke 2AC Voltage Tester 5-Pack is ideal when you require multiple voltage testers for each member of your team and is the latest addition to the VoltAlert™ AC non-contact voltage tester family. The tip of the pocket-sized tester will glow red when within close proximity of an outlet, terminal strip, or power cord where voltage is present. The 2 AC is always on, with a battery check function to make sure the tester is working properly. Review the Fluke 2AC data sheet for all technical specifications.

 

 

 FEATURES

  • Non-contact voltage detection from 90 to 1000 V AC.
  • Innovative ‘Battery Check’ ensures the battery is in good condition.
  • Use of the Battery Check function is optional and for convenience only, it is not intended as a substitute for checking the unit on a known live source before and after use.
  • Integrated clip design, optimized for pocket storage.

 

SET INCLUDES

  • Fluke 2AC Voltage Tester 5-Pack.
  • Batteries.
  • User Manual.

 

Additional information

Operating Principles

Senses the steady state electrostatic field produced by AC voltage through insulation without requiring contact to the bare conductor. A red glow at the tip indicates the presence of voltage.

Safety Compliance

Meets IEC 61010-1:2001, UL 61010-1 (2nd ed.), CAN/CSA-C22.2 No. 61010-1-04, and ISA-82.02.01 Pollution Degree 2

EMC Compliance

Meets IEC 61326-1:2006

Operating

90 V AC to 1000 V AC, CAT IV 1000 V rated

Temperature (Operating and Storage)

-10°C to 50°C (-14°F to 122°F)

Operating Humidity Ranges

0% to 95% (0°C to 30°C)
0% to 75% (30°C to 40°C)
0% to 45% (40°C to 55°C)

Altitude

2000 m (CAT IV 1000 V)

Cleaning

Clean with damp cloth

Battery Life

Typical battery life of greater than one year

Warranty Period

Two years

Scope of Delivery

  • 5x Fluke 2AC Voltage Tester.
  • Batteries.
  • User Manual.

 

Product Warranty

The Fluke 2AC Non-Contact Voltage Tester carries a 2-year limited warranty against manufacture default. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Safety Information

Safety Information

  • A Warning identifies conditions and procedures that are dangerous to the user.
  • To prevent possible electrical shock, fire, or personal injury: Carefully read all instructions.
  • Read all safety information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Use only correct measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Remove all probes, test leads, and accessories before the battery door is opened.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Remove the input signals before you clean the Product.
  • Have an approved technician repair the Product.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Use only specified replacement parts.
  • Use only specified replacement fuses.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not use in CAT III or CAT IV environments without the protective cap installed. The protective cap decreases the exposed probe metal to <4 mm. This decreases the possibility of arc flash from short circuits.
  • To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product to the circuit when you measure the current. Connect the Product in series with the circuit.
  • For safe operation and maintenance of the product, repair the Product before use if the batteries leak.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.