INRUSH FUNCTION

FLUKE 319 True RMS AC/DC Clamp Meter 1000A

AAA | 600V AC DC | 1000A AC DC | 4000Ω

R6,790.00

FloatOr as low as R1,697.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK4232067

The Fluke 319 True-RMS AC/DC Clamp Meter is designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. The 319 offers AC/DC current measurements and has a higher resolution for loads below 40 A as well as also being equipped with In-rush current and Frequency functions for testing motors, lighting, etc. Review the Fluke 319 data sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Rugged, easy-to-use digital clamp meter.

The Fluke 319 True-RMS AC/DC Clamp Meter is designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. The 319 offers AC/DC current measurements and has a higher resolution for loads below 40 A as well as also being equipped with In-rush current and Frequency functions for testing motors, lighting, etc. Review the Fluke 319 data sheet for all technical specifications.

 

 

FEATURES

  • Unique 40A high-precision low current measurement–0.01A high-resolution, 1.6% high-precision measurement.
  • The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces.
  • A large backlight display facilitates readings in dark environments.
  • Starting current (inrush) functionality allows measurement of the starting current of electrical and lighting equipment, for example.
  • Current frequency measurement.
  • Precision down to 0.01A and 0.1V.
  • 1000A AC/DC current measurement.
  • 600V AC/DC voltage measurement.
  • 4000Ω resistance measurement.
  • Continuity beeper.
  • The auto-off function enhances battery life.
  • ‘hold’ function for capturing a measurement result on the screen.

 

SET INCLUDES

  • Fluke 319 True-RMS AC/DC Clamp Meter.
  • Test Leads.
  • Soft Carrying Case.
  • Three AAA batteries (Installed).
  • 317/319 User Manual.

FLUKE 319 True-RMS AC/DC Clamp Meter

Additional information

General specifications

Digital display

6000 count resolution

Low battery Indication

Displays a signal when the batteries are below their required voltage

Power source

Three AAA IEC LR03 batteries

Clamp opening size

37 mm

Jaw diameter

37 mm

Dimensions (L x W x H)

162.4 x 58.25 x 30.5 mm

Weight

Approximately 13.5 oz (384 g) (batteries included)

Auto range

Available in Ohms

Safety

CE
EN/IEC 61010-1 and IEC 61010-2-032
Measurement Category: 600V CAT III

Electrical specifications

Current AC

Range – 40.00 A, 600.0 A, 1000 A
Resolution – 0.01 A, 0.1 A, 1 A
Accuracy – 1.6% ±6 digit (50-60 Hz) {40 A}, 2.5% ±8 digit (60-500 Hz) {40 A}, 1.5% ±5 digit (50-60 Hz) {600/1000 A}, 2.5% ±5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2 -3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response – RMS

Current DC

Range – 40.00 A, 600.0 A, 1000 A
Resolution – 0.01 A, 0.1 A, 1 A
Accuracy – 1.6% ±6 digit (40 A), 1.5% ±5 digit (600/1000 A)

Voltage AC

Range – 600.0 V
Resolution – 0.1 V
Accuracy – 1.5% ±5 digit (20-500Hz)
AC response – RMS

Voltage DC

Range – 600.0 V
Resolution – 0.1 V
Accuracy – 1% ±4 digit

Resistance

Range – 400.0 Ω, 4000 Ω
Resolution – 0.1 Ω, 1 Ω
Accuracy – 1% ±5 digit

Continuity

≤ 30 Ω

Inrush

Integration time – 100 ms

Frequency

Range – 5.0 – 500.0 Hz
Accuracy – 0.5% ±5 digit
Trigger Level – 10 – 100 Hz ≥ 5 A, 5 – 10 Hz, 100 – 500 Hz ≥ 10 A

Notes

-The accuracy specifications apply at 73 °F ±41 °F (23 °C ±5 °C)
-Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C.
-True RMS for ac V and ac A accuracy is specified from 5% to 100% of the range.

Environmental specifications

Temperature

Operating temperature: 14°F to 122°F (-10 °C to 50 °C)
Storage temperature: -40 °F to 140 °F (-40 °C to 60 °C)

Operating humidity

Non-condensing (< 50 °F) (< 10 °C)
90% RH (50 °F to 86 °F) (10 °C to 30 °C)
75% RH (86 °F to 104 °F) (30 °C to 40 °C)
45% RH (104 °F to 122 °F) (40 °C to 50 °C)
(Without condensation)

Altitude

Operating altitude – 1 mile (2000 meters) above mean sea level
Storage altitude – 7 miles (12,000 meters) above mean sea level

IP Rating

IP40

Vibration requirements

Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis

Drop test requirements

3 ft (1 m) drop test, six sides, oak floor

EMI, RFI, EMC

Instrument unspecified for use in EMC field ≥ 0.1 V/m

Temperature coefficients

0.1x (specified accuracy)/ °C
(<64 °F or > 82° F)
(<18 °C or > 28 °C)

Scope of Delivery

  • Fluke 319 Digital Clamp Meter.
  • Test Leads
  • Soft Carrying Case
  • Three AAA batteries (Installed)
  • 317/319 User Manual

Product Warranty

The Fluke 319 carries a 1-year limited warranty against manufacture defects. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Clamp Guide

Safety Information

Safety Information

  • A Warning identifies conditions and procedures that are dangerous to the user.
  • To prevent possible electrical shock, fire, or personal injury: Carefully read all instructions.
  • Read all safety information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Use only correct measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Remove all probes, test leads, and accessories before the battery door is opened.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Remove the input signals before you clean the Product.
  • Have an approved technician repair the Product.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Use only specified replacement parts.
  • Use only specified replacement fuses.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not use in CAT III or CAT IV environments without the protective cap installed. The protective cap decreases the exposed probe metal to <4 mm. This decreases the possibility of arc flash from short circuits.
  • To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product to the circuit when you measure the current. Connect the Product in series with the circuit.
  • For safe operation and maintenance of the product, repair the Product before use if the batteries leak.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.