THREE-PHASE

FLUKE 9040EUR Phase Rotation Indicator

40-700V | 15-400HZ | CAT III 600V | CAT IV 300V

R9,930.00

FloatOr as low as R2,482.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK4014969

The Fluke 9040 is effective for measuring phase rotation in all areas where three-phase supplies are used to feed motors, drives and electrical systems. It provides a clear indication of the 3 phases via an LCD display and the phase rotation direction to determine correct connections. Review the Fluke 9040 data sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Meets the needs of most industrial and residential temperature applications.

The Fluke 9040EUR Phase Rotation Indicator is effective for measuring phase rotation in all areas where three-phase supplies are used to feed motors, drives and electrical systems. It provides a clear indication of the 3 phases via an LCD display and the phase rotation direction to determine correct connections.

It allows rapid determination of phase sequence and has a voltage (up to 700 V) and frequency range suitable for commercial and industrial applications. The included test probes have a variable clamping range for safe contact, also in industrial sockets. Review the Fluke 9040 data sheet for all technical specifications.

 

Fluke 9040EUR Phase Rotation Indicator Showcase

FLUKE 9040EUR Phase Rotation Indicator

FEATURES

  • 3-phase indication.
  • Indication of phase rotation.
  • Clear LCD display.
  • Battery not required.

 

SET INCLUDES

  • Fluke 9040EUR.
  • Slim-Reach™ test probes (black) 1000 V CAT III/600 V CAT IV.
  • Self-retaining test probes, 1000 V CAT II.
  • Alligator clips, 1000 V CAT III/600 V CAT IV.
  • Users Manual.

Additional information

Technical Specifications

‎‎‎

Voltage Range

40-700 V

Frequency Range

15-400 Hz

Operating Timer

Continuous

Environmental Specifications

‎‎‎

Operating Temperature

0°C to 40°C

Dust/Water Resistance

IP 40

Safety Specifications

‎‎‎

Electrical Safety

EN 61010,
EN 61557-7

Overvoltage category

CAT III, 600 V
CAT IV, 300V

Mechanical and General Specifications

‎‎‎

Size

124 x 61 x 27 mm

Weight

200 g

Power supply

From unit under test

Warranty

1 Year

Scope of Delivery

  • Fluke 9040EUR Phase Rotation Indicator.
  • 3x Slim-Reach™ test probes (black) 1000 V CAT III/600 V CAT IV.
  • 3x Self-retaining test probes, 1000 V CAT II.
  • 3x Alligator clips, 1000 V CAT III/600 V CAT IV.
  • Users Manual.

Product Warranty

The Fluke 9040EUR carries a 1-year limited warranty against manufacture defects. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Safety Information

Safety Information

  • A Warning identifies conditions and procedures that are dangerous to the user.
  • To prevent possible electrical shock, fire, or personal injury: Carefully read all instructions.
  • Read all safety information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Use only correct measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Remove all probes, test leads, and accessories before the battery door is opened.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Remove the input signals before you clean the Product.
  • Have an approved technician repair the Product.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Use only specified replacement parts.
  • Use only specified replacement fuses.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not use in CAT III or CAT IV environments without the protective cap installed. The protective cap decreases the exposed probe metal to <4 mm. This decreases the possibility of arc flash from short circuits.
  • To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product to the circuit when you measure the current. Connect the Product in series with the circuit.
  • For safe operation and maintenance of the product, repair the Product before use if the batteries leak.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.