ELECTRICAL TESTERS | HOLSTER

FLUKE T5-1000 Electrical Tester Kit with H5 Holster and 1AC II Voltage Tester

12.9MM | 0-1000V | 0-1000Ω | 90-1000 VAC

R7,290.00

FloatOr as low as R1,822.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK2098657

The FLUKE T5-1000/1ACII Electrical Kit with Holster is designed to help electricians and HVAC technicians solve problems quicker. The Fluke T5-1000 Electrical Tester is a versatile troubleshooting tool to carry to every job site. The portable 1AC II non-contact voltage tester from Fluke is easy to use – just touch the tip to a terminal strip, outlet, or supply cord. Review the Fluke T5-1000, 1AC II, and H5 product data sheets for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Excellent electrical combo that helps you get a lot done.

The FLUKE T5-1000/1ACII Electrical Kit with Holster is designed to help electricians and HVAC technicians solve problems quicker. The Fluke T5-1000 Electrical Tester is a versatile troubleshooting tool to carry to every job site. Use it to check voltage, continuity, and current with one compact tool. the OpenJaw™ design allows for fast and easy current measurements without needing to make metallic contact, just slide a wire into the open fork.

The portable 1AC II non-contact voltage tester from Fluke is easy to use – just touch the tip to a terminal strip, outlet, or supply cord. When the tip glows red and the unit beeps, you know there’s voltage present. Electricians, maintenance, service, safety personnel, and homeowners can quickly test for energized circuits in the workplace or at home and even detect miswires of an electrical outlet. Review the Fluke T5-1000, 1AC II, and H5 product data sheets for all technical specifications.

 

FLUKE T5-1000 FEATURES

  • Included in the Fluke T5-1000/1ACII Electrical Kit with Holster.
  • OpenJaw™ design: measure current without breaking the circuit.
  • The tester automatically selects AC or DC voltage, up to 1000 V.
  • Work in tight spaces with detachable Slim Reach probe tips.
  • Hands-free working when using the test lead holder to make the meter an “extended handle” for the probe.
  • A CAT III 1000V, CAT IV 600 V rating
  • T5-1000 Electrical Tester is able to withstand a 3m drop.
  • Auto-off mode to conserve battery life
  • Fits into the H5 holster that attaches to a belt and neatly stows test leads.

 

FLUKE 1AC II FEATURES

  • Be aware of voltage easily – the tip glows red and a beeper sounds when voltage is detected (can be disabled).
  • Continuous self-test so you always know it’s working.
  • Voltage detection range for wide application use – 90 V to 1000 V AC or 200 V to 1000 V AC.
  • Audible/Silent mode for added convenience.
  • Rated to CAT IV 1000 V for added protection.
  • CE and CSA approved.

 

FLUKE H5 HOLSTER FEATURES

  • Rugged fabric holster includes flap for lead storage and built-in belt loop.
  • Fits Fluke T3 and T5 testers.
  • One year warranty.

Additional information

Fluke T5-1000 Voltage, Continuity and Current Tester

‎‎‎

Specifications

‎‎‎

Jaw opening

12.9 mm (0.5 in)

Max wire size

1/0 THHN Cable

Current range AC rms

0 to 100.0 A

Accuracy AC current (50/60 Hz)

3% ± 3 counts

AC response

Averaging

Voltage range AC/DC

0 to 1000 V

Voltage accuracy

AC – 1.5% ± 2 counts
DC – 1% ± 1 count

Resistance range

0 to 1000 Ω

Continuity beeper threshold

On at < 25 Ω, off at > 400 Ω

Volts indicator LED threshold

Guaranteed on by 30 V AC

Environmental Specifications

‎‎‎

Operating Temperature

-10°C to 50°C (-14°F to 122°F)

Storage temperature

-30°C to 60°C

Humidity (without condensation)

0% to 95% (5°C to 30°C);
0% to 75% (30°C to 40°C);
0% to 45% (40°C to 50°C)

Dust/water resistance

Yes

Operating Altitude

3000 m

Temperature coefficient

0.1 x (specified accuracy)/°C (< 18°C or> 28°C)

Safety Specifications

‎‎‎

Measurement Category

IEC 61010-2-032, IEC61010-2-033: CAT IV 600 V / CAT III 1000 V, 100 A ac

Agency approvals

CSA, TUV

Maximum voltage

1000 V between any terminal and earth ground

Mechanical and General Specifications

‎‎‎

Size

30.5 x 51 x 203 mm

Weight

300 g

Warranty

Two-years

Battery Life

Typical battery life of greater than 1 year

Battery type

2 x AA

Low battery indicator

Yes

Current sensor opening

12.9 mm

Fluke 1AC II Non-Contact Voltage Tester

‎‎‎

1AC II Specifications

‎‎‎

1AC II Operating Principles

Senses the steady state electrostatic field produced by AC voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage.

1AC II Voltage sensing ranges

Nominally, 90 V AC to 1000 V AC

1AC II Detector tip style

Flat-tip

1AC II Light source

One high-intensity red LED

1AC II Safety

IEC 61010-1: Pollution Degree 2, IEC 61010-2-030: CAT IV 1000 V

1AC II EMC

IEC 61326-1: Portable

1AC II IP Rating

IP 40

1AC II Operating Temperature

-10°C to 50°C (-14°F to 122°F)

1AC II Operating Humidity Ranges

0% to 95% (0°C to 30°C)
0% to 75% (30°C to 40°C)
0% to 45% (40 to 55°C)

1AC II Operating Altitude

3000 m

1AC II Cleaning

Clean with damp cloth

1AC II Batteries

2 AAA alkaline batteries included

1AC II Battery Life

Typical battery life of greater than 1 year

1AC II Warranty Period

Two years

Notes

Product does not respond to random electrostatic discharge.

Scope of Delivery

  • Fluke T5-1000 Electrical Tester.
  • 4 mm detachable probes.
  • Fluke 1AC II Voltage Tester.
  • Fluke H5 Electrical Tester Holster.
  • Instruction sheet.

Product Warranty - T5-1000

The Fluke T5-1000 carries a 2-year limited warranty against manufacture defects. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Product Warranty - 1AC II

The Fluke 1AC II Non-Contact Voltage Tester carries a 2-year limited warranty against manufacture default. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Safety Information

Safety Information

  • A Warning identifies conditions and procedures that are dangerous to the user.
  • To prevent possible electrical shock, fire, or personal injury: Carefully read all instructions.
  • Read all safety information before you use the Product.
  • Use the Product only as specified, or the protection supplied by the Product can be compromised.
  • Do not use the Product around explosive gas, vapor, or in damp or wet environments.
  • Do not use the Product if it is damaged.
  • Disable the Product if it is damaged.
  • Do not use the Product if it operates incorrectly.
  • Examine the case before you use the Product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • Use only correct measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Measure a known voltage first to make sure that the Product operates correctly.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground.
  • Do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
  • Keep fingers behind the finger guards on the probes.
  • Remove all probes, test leads, and accessories before the battery door is opened.
  • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of a Product, probe, or accessory.
  • Remove the input signals before you clean the Product.
  • Have an approved technician repair the Product.
  • Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 °C. If the batteries are not removed, battery leakage can damage the Product.
  • Replace the batteries when the low battery indicator shows to prevent incorrect measurements.
  • Use only specified replacement parts.
  • Use only specified replacement fuses.
  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use test leads if they are damaged. Examine the test leads for damaged insulation and measure a known voltage.
  • Do not use in CAT III or CAT IV environments without the protective cap installed. The protective cap decreases the exposed probe metal to <4 mm. This decreases the possibility of arc flash from short circuits.
  • To prevent possible electrical shock, fire or personal injury, do not use the HOLD function to measure unknown potentials. When HOLD is turned on, the display does not change when a different potential is measured.
  • To prevent possible electrical shock, fire, or personal injury, remove circuit power before you connect the Product to the circuit when you measure the current. Connect the Product in series with the circuit.
  • For safe operation and maintenance of the product, repair the Product before use if the batteries leak.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.