ACCURATE. NON-INTRUSIVE

FLUKE i30 AC/DC Current Clamp (30 A)

9V | 300V | 5 mA-30 ADC | 30 mA-20 AAC RMS

R19,690.00

FloatOr as low as R4,922.50 / month interest-free, using your existing credit card. For orders over R3,000.00.How it works

SKU FLK2584920

The i30 current clamp is based on Hall Effect technology for use in the measurement of both DC and AC current. The i30 may be used in conjunction with multimeters, recorders and other suitable recording instruments for accurate non-intrusive current measurement. Review the Fluke i30 data sheet for all technical specifications.

We offer free nationwide delivery for all orders over R1500.

Any order under R1500 will be charged R175 for delivery

OZOW – Instant EFT: lightning-fast bank-to-bank payments.

Peach Payments – Checkout via Credit/Debit Card or Mobicred.

Bank Transfer – Manually transfer funds into our account.

Mobicred – Finance your purchase entirely or partially up to a maximum of R50,000. Apply Here

Float – For orders over R3000. Up to 4 interest-free installments, using your existing credit card.

In stock with supplier: delivery in 2-4 working days

Description

 

Ideal multimeter companion.

The Fluke i30 AC/DC Current Clamp is based on Hall Effect technology for use in the measurement of both DC and AC current. The i30 may be used in conjunction with multimeters, recorders and other suitable recording instruments for accurate non-intrusive current measurement. Review the Fluke i30 data sheet for all technical specifications.

 

FEATURES

  • DC range – 30 mA to 30 A DC.
  • AC range – 30 mA to 20 A AC RMS.
  • For use in conjunction with multimeters and recorders.

 

Additional information

Electrical Specifications

‎‎‎

Specified current range

30 mA to 30 A DC, 30 mA to 20 A AC rms

Usable current range

5 mA to 30 A DC, 30 mA to 20 A AC rms

Crest Factor

1.4 in

Output sensitivity

100 mV/A

Accuracy (at +25°C)

±1% of reading ±2 mA

Resolution

±1 mA

Load impedance

> 10 k Ohms and ≤ 100pF

Conductor position sensitivity

±1% relative to center reading

Frequency range

DC to 20 kHz (-0.5 dB)

Temperature coefficient

±0.01% of reading/°C

Power supply

9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator

Working voltage (see Safety Standards section)

300 V AC rms or DC

General Sepecifications

‎‎‎

Maximum conductor size

19 mm diameter

Output connection

4 mm safety connector

Output zero

Manual adjust via thumbwheel

Cable length

1.5 meters

Operating temperature range

0°C to +50°C

Storage temperature range (with battery removed)

-20°C to +85°C

Operating humidity

15% to 85% (non-condensing)

Weight

250 g

Safety

IEC 61010-1, Pollution Degree 2
IEC 61010-2- 032: CAT III 300V
Use of the probe on uninsulated conductors is limited to 300 V ac RMS or dc and frequencies below 1 kHz.

EMC Compatibility

IEC 61326-1: Portable Electromagnetic Environment

Scope of Delivery

  • Fluke i30 AC/DC Current Clamp.

Product Warranty

The FLUKE i30 carries a 1-year limited warranty against manufacture defects. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.

Top Dog Tool Shop is here to support all your after-sale needs. Should a warranty claim occur, Top Dog Tool Shop will facilitate the claim but the approval or non-approval there-of is entirely at the discretion of the Importer/Manufacturer.

Safety Information

Safety Instructions

Please read this section carefully. It will make you familiar with the most important safety instructions for handling your product. In this instruction sheet, a Warning identifies conditions and actions that pose hazard(s) to the user. A Caution identifies conditions and actions that may damage the calibrator or the test instruments.

The i30s and i30 may only be used and handled by qualified personnel. To avoid personal injury, follow these precautions:

  • To avoid electric shock, use caution during installation and use of this product; high voltages and currents may be present in the circuit under test.
  • Do not use the product if damaged. Always connect the probe to the display device before it is installed around the conductor.
  • Always ensure the probe is removed from any live electric circuit, and leads are disconnected before removing the battery cover.
  • Use the Current Probe only as specified in the operating instructions; otherwise, the current probe’s safety features may not protect you.
  • Adhere to local and national safety codes. Individual protective equipment must be used to prevent the shock and arc blast injury where hazardous live conductors are exposed.
  • Do not hold the Current Probe anywhere beyond the tactile indicator.
  • Before each use, inspect the Current Probe. Look for cracks or missing portions of the Current Probe housing or output cable insulation. Also, look for loose or weakened components. Pay particular attention to the insulation surrounding the jaws.
  • Use caution when working with voltages above 60 V dc, 30 V ac RMS or 42 V ac peak. Such voltages pose a shock hazard.
  • Use of this equipment is designed to protect against transients in equipment in fixed equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings.
  • Use of this equipment in a manner not specified herein may impair the protection provided by the equipment.
  • CAT III equipment is designed to protect against the transients in the equipment in fixed equipment installations, such as distribution panels, feeders and short branch circuits, and the lighting systems in large buildings.

 

For additional safety information, visit the Fluke Safety Resource Center.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Open Chat
Welcome to Top Dog Tool Shop. Give us a buzz and get the answers and help you need: 011 425 1240

Not your thing? Click "open chat" to start a WhatsApp conversation.

We are available weekdays from 8am to 5pm.